Evidence map›Paper›PMID 37836914›Full record

ArticleSensors (Basel, Switzerland)2023

Optimal Frequency and Wireless Power Budget for Miniature Receivers in Obese People.

Tom Van de Steene, Emmeric Tanghe, Luc Martens, Carmine Garripoli, Stefano Stanzione, Wout Joseph

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.3field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Tom Van de SteeneDepartment of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium.ORCID 0000-0002-3636-8144
Emmeric TangheDepartment of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium.
Luc MartensDepartment of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium.
Carmine GarripoliHolst Centre/imec, 5656 AE Eindhoven, The Netherlands.
Stefano StanzioneHolst Centre/imec, 5656 AE Eindhoven, The Netherlands.
Wout JosephDepartment of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium.ORCID 0000-0002-8807-0673
Ghent University · BEHolst Centre (Netherlands) · NL

Funding

Research Foundation - Flanders G003415N
6 · The paper itself

Abstract

This study investigates wireless power transfer for deep in-body receivers, determining the optimal frequency, power budget, and design for the transmitter and receiver. In particular, the focus is on small, in-body receivers at large depths up to 20 cm for obese patients. This enables long-term monitoring of the gastrointestinal tract for all body types. Numerical simulations are used to investigate power transfer and losses as a function of frequency and to find the optimal design at the selected frequency for an obese body model. From all ISM-frequencies in the investigated range (1 kHz-10 GHz), the value of 13.56 MHz yields the best performance. This optimum corresponds to the transition from dominant copper losses in conductors to dominant losses in conductive tissue. At this frequency, a transmitting and receiving coil are designed consisting of 12 and 23 windings, respectively. With a power transfer efficiency of 2.70×10-5, 18 µW can be received for an input power of 0.68 W while still satisfying exposure guidelines. The power transfer is validated by measurements. For the first time, efficiency values and the power budget are reported for WPT through 20 cm of tissue to mm sized receivers. Compared to WPT at higher frequencies, as commonly used for small receivers, the proposed system is more suitable for WPT to large depths in-body and comes with the advantage that no focusing is required, which can accommodate multiple receivers and uncertainty about receiver location more easily. The received power allows long-term sensing in the gastrointestinal tract by, e.g., temperature, pressure, and pH sensors, motility sensing, or even gastric stimulation.

Indexed as

Prostheses and ImplantsWireless TechnologyElectric ConductivityElectric Power SuppliesEquipment DesignHumanscoil designdeep implantsingestiblesminiature implantable medical devicesnumerical simulationsresonant inductive power transferwireless power transfer

Identifiers

PMID37836914
PMCPMC10574982
OpenAlexW4387059204

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.