Evidence map›Paper›PMID 37836910›Full record

ArticleSensors (Basel, Switzerland)2023

Modeling of Ammunition Dynamic Pressure Measurement Chain in Ballistic Tests.

Caio Bittencourt Cardoso Felix, Khrissy Aracélly Reis Medeiros, Carlos Roberto Hall Barbosa

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 48% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Caio Bittencourt Cardoso FelixPostgraduate Programme in Metrology, Pontifical Catholic University of Rio de Janeiro, Marquês de São Vicente Street, 225, Gávea, Rio de Janeiro 22451-900, Brazil.ORCID 0009-0008-4069-5405
Khrissy Aracélly Reis MedeirosMechanical Engineering Department, Optical Fiber Sensors Laboratory, Pontifical Catholic University of Rio de Janeiro, Marquês de São Vicente Street, 225, Gávea, Rio de Janeiro 22451-900, Brazil.ORCID 0000-0001-8577-9671
Carlos Roberto Hall BarbosaPostgraduate Programme in Metrology, Pontifical Catholic University of Rio de Janeiro, Marquês de São Vicente Street, 225, Gávea, Rio de Janeiro 22451-900, Brazil.ORCID 0000-0003-0753-9044
Pontifícia Universidade Católica do Rio de Janeiro · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The use of piezoelectric transducers for internal dynamic pressure measurements in ammunition testing provides a significant advantage in the development and performance analysis of weapons and ammunition. Knowledge of the electrical characteristics of the dynamic pressure measurement chain, which includes the piezoelectric transducer and the charge amplifier, is a relevant condition for the design of interior ballistics pressure measurement systems. Thus, this study aims to characterize and model a piezoelectric transducer and its associated charge amplifier. First, the piezoelectric transducer was characterized using impedance analysis and modeled using a least squares curve-fitting tool, according to the Butterworth-Van Dyke model. Next, the charge amplifier was characterized through response analysis based on known inputs and modeled using LTSpice simulation techniques and the least squares curve-fit tool. Consequently, a measurement chain model is presented and simulated for two cases with different impulse signals. The first impulse signal was obtained from an interior ballistics computer simulation, and in the second case, it was considered the negative step signal characteristic of the calibration of piezoelectric transducers by means of dead weight. From the simulations, it was possible to verify the effectiveness of the model, which provided results with a low error in relation to the original pressure curve, and its applicability is demonstrated by the result of the simulation of the pressure variation in the calibration, where the attenuation of the signal can be visualized as the characteristic of the input curve changes.

Indexed as

equivalent circuitimpedance analysisinterior ballisticspiezoelectric transducerpressure measurement

Identifiers

PMID37836910
PMCPMC10575385
OpenAlexW4387058599

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.