Evidence map›Paper›PMID 37835805›Full record

ArticleDiagnostics (Basel, Switzerland)2023

Feasibility of In Vivo Metal Artifact Reduction in Contrast-Enhanced Dedicated Spiral Breast Computed Tomography.

Matthias Wetzl, Evelyn Wenkel, Chrisitan Steiding, Veikko Ruth, Julius Emons, Martin N Wasser, Michael Uder, Sabine Ohlmeyer

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.1field-weighted citation impact, top 59% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Matthias WetzlDepartment of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054 Erlangen, Germany.ORCID 0000-0001-9980-9528
Evelyn WenkelDepartment of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054 Erlangen, Germany.
Chrisitan SteidingAB-CT-Advanced Breast-CT GmbH, Henkestrasse 91, 91052 Erlangen, Germany.
Veikko RuthAB-CT-Advanced Breast-CT GmbH, Henkestrasse 91, 91052 Erlangen, Germany.
Julius EmonsDepartment of Gynecology and Obstetrics, University Hospital Erlangen, Universitätsstraße 21/23, 91054 Erlangen, Germany.ORCID 0000-0002-2520-4443
Martin N WasserDepartment of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands.ORCID 0000-0002-7020-5242
Michael UderDepartment of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054 Erlangen, Germany.
Sabine OhlmeyerDepartment of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054 Erlangen, Germany.ORCID 0000-0001-9163-8840
Universitätsklinikum Erlangen · DELeiden University Medical Center · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRadiopaque breast markers cause artifacts in dedicated spiral breast-computed tomography (SBCT). This study investigates the extent of artifacts in different marker types and the feasibility of reducing artifacts through a metal artifact reduction (MAR) algorithm.

methodsThe pilot study included 18 women who underwent contrast-enhanced SBCT. In total, 20 markers of 4 different types were analyzed for artifacts. The extent of artifacts with and without MAR was measured via the consensus of two readers. Image noise was quantitatively evaluated, and the effect of MAR on the detectability of breast lesions was evaluated on a 3-point Likert scale.

resultsBreast markers caused significant artifacts that impaired image quality and the detectability of lesions. MAR decreased artifact size in all analyzed cases, even in cases with multiple markers in a single slice. The median length of in-plain artifacts significantly decreased from 31 mm (range 11-51 mm) in uncorrected to 2 mm (range 1-5 mm) in corrected images (

conclusionMAR is feasible in SBCT and improves the image quality and detectability of lesions.

Indexed as

breast CTbreast imagingcomputed tomographymetal artifact reduction

Identifiers

PMID37835805
PMCPMC10572310
OpenAlexW4387105416

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.