Evidence map›Paper›PMID 37833661›Full record

ArticleBMC medical informatics and decision making2023

Negation recognition in clinical natural language processing using a combination of the NegEx algorithm and a convolutional neural network.

Guillermo Argüello-González, José Aquino-Esperanza, Daniel Salvador, Rosa Bretón-Romero, Carlos Del Río-Bermudez, Jorge Tello, Sebastian Menke

Abstract read
In one paragraph

Article in BMC medical informatics and decision making, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Guillermo Argüello-GonzálezMedSavana SL, Madrid, 28004, Spain.
José Aquino-EsperanzaMedSavana SL, Madrid, 28004, Spain.
Daniel SalvadorMedSavana SL, Madrid, 28004, Spain.
Rosa Bretón-RomeroSavana Research, Madrid, SL, 28004, Spain.
Carlos Del Río-BermudezSavana Research, Madrid, SL, 28004, Spain.
Jorge TelloMedSavana SL, Madrid, 28004, Spain.
Sebastian MenkeMedSavana SL, Madrid, 28004, Spain. smenke@savanamed.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundImportant clinical information of patients is present in unstructured free-text fields of Electronic Health Records (EHRs). While this information can be extracted using clinical Natural Language Processing (cNLP), the recognition of negation modifiers represents an important challenge. A wide range of cNLP applications have been developed to detect the negation of medical entities in clinical free-text, however, effective solutions for languages other than English are scarce. This study aimed at developing a solution for negation recognition in Spanish EHRs based on a combination of a customized rule-based NegEx layer and a convolutional neural network (CNN).

methodsBased on our previous experience in real world evidence (RWE) studies using information embedded in EHRs, negation recognition was simplified into a binary problem ('affirmative' vs. 'non-affirmative' class). For the NegEx layer, negation rules were obtained from a publicly available Spanish corpus and enriched with custom ones, whereby the CNN binary classifier was trained on EHRs annotated for clinical named entities (cNEs) and negation markers by medical doctors.

resultsThe proposed negation recognition pipeline obtained precision, recall, and F1-score of 0.93, 0.94, and 0.94 for the 'affirmative' class, and 0.86, 0.84, and 0.85 for the 'non-affirmative' class, respectively. To validate the generalization capabilities of our methodology, we applied the negation recognition pipeline on EHRs (6,710 cNEs) from a different data source distribution than the training corpus and obtained consistent performance metrics for the 'affirmative' and 'non-affirmative' class (0.95, 0.97, and 0.96; and 0.90, 0.83, and 0.86 for precision, recall, and F1-score, respectively). Lastly, we evaluated the pipeline against two publicly available Spanish negation corpora, the IULA and NUBes, obtaining state-of-the-art metrics (1.00, 0.99, and 0.99; and 1.00, 0.93, and 0.96 for precision, recall, and F1-score, respectively).

conclusionNegation recognition is a source of low precision in the retrieval of cNEs from EHRs' free-text. Combining a customized rule-based NegEx layer with a CNN binary classifier outperformed many other current approaches. RWE studies highly benefit from the correct recognition of negation as it reduces false positive detections of cNE which otherwise would undoubtedly reduce the credibility of cNLP systems.

Indexed as

AlgorithmsNatural Language ProcessingElectronic Health RecordsHumansLanguageNeural Networks, ComputerClinical Natural Language ProcessingCNNElectronic health recordsNegationNegEx

Identifiers

PMID37833661
PMCPMC10576331

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.