Evidence map›Paper›PMID 37833471›Full record

ArticleCanadian journal of anaesthesia = Journal canadien d'anesthesie2023

The effect of class 3 obesity on the functionality of supraglottic airway devices: a historical cohort analysis with propensity score matching.

Patrick Hartsuyker, Marcelo E Kanczuk, David Lawn, Salwa Beg, Tesfaye S Mengistu, Matthew Hiskens

Open access · bronzeAbstract read
PubMed Publisher
In one paragraph

Article in Canadian journal of anaesthesia = Journal canadien d'anesthesie, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
1.7field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.

  1. Guideline
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Patrick HartsuykerJames Cook University, North Mackay, QLD, Australia. patrick.hartsuyker@health.qld.gov.au.ORCID http://orcid.org/0000-0002-2548-7965
Marcelo E KanczukMackay Hospital and Health Service (MHHS), Mackay Base Hospital, Mackay, QLD, Australia.
David LawnMackay Hospital and Health Service (MHHS), Mackay Base Hospital, Mackay, QLD, Australia.
Salwa BegMackay Hospital and Health Service (MHHS), Mackay Base Hospital, Mackay, QLD, Australia.
Tesfaye S MengistuMackay Institute of Research and Innovation, Mackay Base Hospital, Mackay, QLD, Australia.
Matthew HiskensMackay Institute of Research and Innovation, Mackay Base Hospital, Mackay, QLD, Australia.
Mackay Base Hospital · AUThe University of Queensland · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeSupraglottic airway devices (SGAs) have been increasingly used as a primary airway in patients undergoing anesthesia as an alternative to endotracheal tubes. Second-generation devices have expanded their applicability to include uses in patients with obesity. Nevertheless, there is limited evidence of SGA suitability for patients with class 3 obesity (body mass index [BMI] ≥ 40 kg·m

methodsWe performed a propensity score matching analysis using inverse probability of treatment weighting to compare the functionality of SGAs in adult patients with class 3 obesity vs without class 3 obesity. These patients underwent surgery at a hospital in Queensland, Australia from November 2017 to September 2020 and had a SGA inserted as part of their anesthetic care. All data were collected from patients' electronic medical records. We included 321 patients in the cohort with class 3 obesity and 471 in the cohort without class 3 obesity (control/comparison). The estimated effect of class 3 obesity on SGAs was calculated using adjusted odds ratios (AORs) with their 95% confidence intervals (CIs).

resultsThe overall weighted prevalence of nonfunctional SGAs was 3.2%, with a significantly higher rate in the class 3 obesity cohort compared with the control cohort (4.7% vs 2.1%) (P = 0.04). This adjusted analysis illustrates that class 3 obesity was associated with an almost four times higher odds of a nonfunctional SGA (odds ratio [OR], 2.3; 95% CI, 1.0 to 5.1; AOR, 3.9; 95% CI, 1.4 to 10.6) than patients without class 3 obesity.

conclusionPatients with class 3 obesity (BMI ≥ 40 kg·m

Indexed as

Laryngeal MasksAdultAirway ManagementAnesthesia, GeneralCohort StudiesHumansIntubation, IntratrachealObesityPropensity Scoreadverse eventsclass 3 obesitylaryngeal mask airwaysafetysupraglottic airway device

Identifiers

PMID37833471
OpenAlexW4387613917

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.