ArticleJournal of clinical monitoring and computing2024
Comparative performance of stimpod electromyography with mechanomyography for quantitative neuromuscular blockade monitoring.
Article in Journal of clinical monitoring and computing, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 11 citations in OpenAlex.
- Spontaneous recovery from rocuronium measured by mechanomyography during 100- or 200-Hz tetanic stimulations compared to normalized train-of-four with acceleromyography.Journal of clinical monitoring and computing · 2025Trial
- Paired assessment of two electromyographic neuromuscular monitors: stimpod NMX450X versus Datex-Ohmeda E-NMT.Journal of clinical monitoring and computing · 2026Article
- A single-centre, randomised comparison of the performance and safety of a novel mechanomyography sensor with electromyography.British journal of anaesthesia · 2026Article
- Advances in Neuromuscular Monitoring Techniques in Anesthesiology: A 2025 Perspective.Medical science monitor : international medical journal of experimental and clinical research · 2025Review
- Train-of-four ratio, counts and post tetanic counts with the Tetragraph electromyograph in comparison to mechanomyography.Journal of clinical monitoring and computing · 2025Article
- Implementation and Feasibility of Mechanomyography in Minimally Invasive Spine Surgery.Journal of personalized medicine · 2025Article
- Evolution of a laboratory mechanomyograph.Journal of clinical monitoring and computing · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe purpose of this study was to compare the Stimpod electromyograph neuromuscular blockade monitor to mechanomyography, which is widely considered to be the reference standard.
methodsThe Stimpod electromyograph was used with its designated electrode array on the same hand as the mechanomyograph. Pairs of train-of-four measurements were recorded every 0.5-2 min. When the train-of-four count was zero on the electromyograph monitor, pairs of post tetanic count measurements were recorded every 2.5 min, instead of train-of-four measurements. Measurements were recorded from immediately after induction of anesthesia until just before emergence. Stimulation current was set to 60 mA with a duration of 200 microsec. The mechanomyography recording system recorded each twitch waveform for analysis. High resolution electromyograph waveforms were also recorded using a datalogger accessory provided by the manufacturer, facilitating inspection of individual waveforms. The administration of neuromuscular blocking drugs was left up to the discretion of the anesthesia care team.
resultsTwenty-three patients contributed 1,088 data pairs suitable for analysis. Bland-Altman analysis of 415 pairs of train-of-four ratios showed a bias of 0.028 and limits of agreement of -0.18 and 0.24. Two hundred seventy-three train-of-four count data pairs were compared by Cohen's quadratically weighted kappa which was calculated to be 0.44, indicating moderate agreement. Three hundred thirty-eight post tetanic count data pairs were compared by Cohen's quadradically weighted kappa which was calculated to be 0.80, indicating substantial agreement.
conclusionThe electromyograph produced results that were comparable to the mechanomyograph.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.