Evidence map›Paper›PMID 37831197›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Long-term clinical and radiological outcome of a cementless titanium-coated total knee arthroplasty system.

Nina Hörlesberger, Maria Anna Smolle, Lukas Leitner, Georg Hauer, Andreas Leithner, Patrick Sadoghi

Open access · hybridAbstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Nina HörlesbergerDepartment of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
Maria Anna SmolleDepartment of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria. maria.smolle@medunigraz.at.
Lukas LeitnerDepartment of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
Georg HauerDepartment of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
Andreas LeithnerDepartment of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
Patrick SadoghiDepartment of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
Medical University of Graz · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionTo ensure a high-quality standard, it is important to frequently evaluate different prostheses models to avoid prostheses with high failure rates. Thus, the aim of the study was to evaluate the long-term outcome of the uncemented titanium-coated total knee arthroplasty (TKA) system (Advanced Coated System (ACS) III, Implantcast, GERMANY). We hypothesized that the ACS III would have a similar performance as other cemented TKA systems. MATERIALS AND

methodsA total of 540 ACS III mobile-bearing knee joint prostheses were implanted in 495 patients. The visual analogue scale (VAS) score, Tegner activity score (TAS), knee society score (KSS), Western Ontario and McMaster (WOMAC) score, and the Short Form 12 (SF-12) score for the evaluation of quality of life (QoL) were taken after at least 9 years of follow-up. In addition, we measured range of motion (ROM) and assessed potential sex differences. In addition, the survival analysis was calculated at a median follow-up of 16.7 years.

resultsAt the final follow-up, 142 patients had died, and 38 had been lost to follow-up. The rate of revision-free implant survival at 16.7 years was 90.0% (95% CI 87.1-92.2%) and the rate of infection-free survival was 97.0% (IQR 95.2-98.2%). The reasons for revision surgery were aseptic loosening (32.9%), followed by infection (27.1%), inlay exchange (15.9%), and periprosthetic fractures (5.7%). At the clinical follow-up visit, the mean VAS score was 1.9 ± 1.9, the median TAS was 3 (IQR 2-4), and the mean KSS for pain and function were 83.5 ± 15.3 and 67.5 ± 25.2, respectively. The mean WOMAC score was 81.1 ± 14.9, and the median SF-12 scores for physical and mental health were 36.9 (IQR 29.8-45.1) and 55.8 (IQR 46.2-61.0), respectively. The mean knee flexion was 102.0° ± 15.4°. Male patients had better clinical outcome scores than female patients [SF-12 mental health score, p = 0.037; SF-12 physical health score, p = 0.032; KSS pain score (p < 0.001), and KSS functional score (p < 0.001)].

conclusionThe ACS III TKA system is a suitable option for the treatment of end-stage osteoarthritis of the knee joint because of its adequate long-term survival. Our findings are in line with published data on similar TKA systems that have shown favourable clinical scores in males. LEVEL OF EVIDENCE: Level III-Retrospective cohort study.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeFemaleHumansKnee JointMalePainQuality of LifeRange of Motion, ArticularRetrospective StudiesTitaniumTreatment OutcomeTitaniumACS IIIOutcome analysisTin-coated prosthesisTotal knee arthroplasty

Identifiers

PMID37831197
PMCPMC10822817
OpenAlexW4387597770

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.