Evidence map›Paper›PMID 37829844›Full record

ArticlePNAS nexus2023

Low-rate smartphone videoscopy for microsecond luminescence lifetime imaging with machine learning.

Yan Wang, Sina Sadeghi, Alireza Velayati, Rajesh Paul, Zach Hetzler, Evgeny Danilov, Frances S Ligler, Qingshan Wei

Abstract read
In one paragraph

Article in PNAS nexus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Development of Time-Resolved Luminescence Measurement Instruments for Biosensing and Bioimaging - An Overview.Measurement : journal of the International Measurement Confederation · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yan WangDepartment of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA.
Sina SadeghiDepartment of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA.
Alireza VelayatiDepartment of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA.ORCID https://orcid.org/0009-0006-8125-2526
Rajesh PaulDepartment of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA.
Zach HetzlerDepartment of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA.
Evgeny DanilovDepartment of Chemistry, North Carolina State University, Raleigh, NC 27695, USA.
Frances S LiglerDepartment of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.ORCID https://orcid.org/0000-0003-4909-2084
Qingshan WeiDepartment of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA.ORCID https://orcid.org/0000-0003-1214-010X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Time-resolved techniques have been widely used in time-gated and luminescence lifetime imaging. However, traditional time-resolved systems require expensive lab equipment such as high-speed excitation sources and detectors or complicated mechanical choppers to achieve high repetition rates. Here, we present a cost-effective and miniaturized smartphone lifetime imaging system integrated with a pulsed ultraviolet (UV) light-emitting diode (LED) for 2D luminescence lifetime imaging using a videoscopy-based virtual chopper (V-chopper) mechanism combined with machine learning. The V-chopper method generates a series of time-delayed images between excitation pulses and smartphone gating so that the luminescence lifetime can be measured at each pixel using a relatively low acquisition frame rate (e.g. 30 frames per second [fps]) without the need for excitation synchronization. Europium (Eu) complex dyes with different luminescent lifetimes ranging from microseconds to seconds were used to demonstrate and evaluate the principle of V-chopper on a 3D-printed smartphone microscopy platform. A convolutional neural network (CNN) model was developed to automatically distinguish the gated images in different decay cycles with an accuracy of >99.5%. The current smartphone V-chopper system can detect lifetime down to ∼75 µs utilizing the default phase shift between the smartphone video rate and excitation pulses and in principle can detect much shorter lifetimes by accurately programming the time delay. This V-chopper methodology has eliminated the need for the expensive and complicated instruments used in traditional time-resolved detection and can greatly expand the applications of time-resolved lifetime technologies.

Indexed as

lifetime imagingmachine learningsmartphone videoscopytime-resolvedV-chopper

Identifiers

PMID37829844
PMCPMC10566544

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.