Evidence map›Paper›PMID 37829800›Full record

ArticleHeliyon2023

Influence of a new motion correction algorithm (CardioCapture) on the correlation between heart rate and optimal reconstruction phase.

Wei Yin, Ruimin Xu, Binghui Zhao, Shuilian Liu, Minjie Wang

Abstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Wei YinDepartment of Radiology, Changhai Hospital of Shanghai, Naval Medical University, NO.168 Chang-hai Road, Shanghai, 200433, China.
Ruimin XuDepartment of Anorectal, Shanghai Pudong New Area Hospital of Traditional Chinese Medicine, NO.340 Xiu-chuan Road, Shanghai, 201200, China.
Binghui ZhaoDepartment of Radiology, Changhai Hospital of Shanghai, Naval Medical University, NO.168 Chang-hai Road, Shanghai, 200433, China.
Shuilian LiuDepartment of Radiology, Changhai Hospital of Shanghai, Naval Medical University, NO.168 Chang-hai Road, Shanghai, 200433, China.
Minjie WangDepartment of Radiology, Changhai Hospital of Shanghai, Naval Medical University, NO.168 Chang-hai Road, Shanghai, 200433, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To investigate the effect of a new motion correction algorithm (CardioCapture) on the correlation between heart rate and optimal reconstruction phase by evaluating the impact of wide detector CT combined with CardioCapture on CCTA image quality. Materials and methods: All cases were examined from April 2021 to September 2021. Two experienced radiologists scored these images on a four-point Likert scale. First, all images were divided into eight groups according to HR (at an interval of 5 bpm). The subjective score of images, the frequency of used CardioCapture, and the proportion of the diastolic reconstruction phase were compared in each group. Then, all cases were divided into two groups, one group was reconstructed using the automatic temporal reconstruction algorithm (Ephase) only, and the other group was reconstructed using the Ephase with the CardioCapture. The relationship between HR and the diastolic reconstruction phase was analyzed by the receiver operator characteristic curve (ROC). Result: The data of 515 patients were studied. With the increase in HR, the subjective image score decreased, the frequency of CardioCapture increased, and the phase ratio of diastolic reconstruction decreased. When the HR was less than 70 bpm, the percentage of excellence image in each group surpassed 94.90%. The highest utilization rate of CardioCapture was 65.22%, and the lowest proportion of diastolic reconstruction was 72.46%. When 70 bpm < HR ≤ 75 bpm, the image excellence rate was 90.43%, the CardioCapture utilization rate was 82.05%, and the diastolic reconstruction rate was 56.41%.When 75 bpm < HR ≤ 80 bpm, the image excellence rate was 87.91%, the CardioCapture utilization rate was 80.65%, and the diastolic reconstruction was 6.45%.When the HR > 80 bpm, the image excellence rate was 80.00%, the CardioCapture utilization rate was 75.00%, and the diastolic reconstruction rate was 22.50%. The best cut-off point between HR and the diastolic reconstruction ROC curve in the groups without CardioCapture was 65 bpm, while that in groups with CardioCapture was 68 bpm. Conclusion: The CardioCapture can effectively improve the image quality of CCTA with high HR. By maintaining the HR below 68 bpm and utilizing the prospective ECG-gated narrow phase axial scan, it is possible to ensure optimal image quality and concurrently reduce radiation dose.

Indexed as

320-Row MSCTCardioCaptureCoronary CT angiographyMotion correction algorithm

Identifiers

PMID37829800
PMCPMC10565690

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.