Evidence map›Paper›PMID 37829619›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2023

Improving quantification of renal fibrosis using

Samuel Border, Avi Rosenberg, Jarcy Zee, Richard Levenson, Kuang-Yu Jen, Pinaki Sarder, Farzad Fereidouni

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 63% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Samuel BorderUniversity of Florida at Gainesville, J. Crayton Pruitt Family Department of Biomedical Engineering.
Avi RosenbergJohns Hopkins Medicine, Department of Pathology.
Jarcy ZeeUniversity of Pennsylvania, Department of Biostatistics, Epidemiology and Informatics.
Richard LevensonUniversity of California Davis Health, Department of Pathology and Laboratory Medicine.
Kuang-Yu JenUniversity of California Davis Health, Department of Pathology and Laboratory Medicine.
Pinaki SarderUniversity of Florida at Gainesville, J. Crayton Pruitt Family Department of Biomedical Engineering.
Farzad FereidouniUniversity of California Davis Health, Department of Pathology and Laboratory Medicine.
University of California, Davis · USUniversity of Florida · USCalifornia University of Pennsylvania · USJohns Hopkins University · US

Funding

Computational Imaging of Renal Structures for Diagnosing DiabeticNephropathyR01DK114485 · NIDDK · UNIVERSITY OF FLORIDA · PI Michael Thomas Eadon, Avi Z Rosenberg · 2018 to 2026
$4.7M
Rapid quantitative renal fibrosis evaluation with dual-mode microscopyR01DK131189 · NIDDK · UNIVERSITY OF CALIFORNIA AT DAVIS · PI Farzad Fereidouni · 2022 to 2026
$2.7M
DUET: Rapid dual-mode microscopy for quantitative slide-based renal fibrosis evaluationR56DK124873 · NIDDK · UNIVERSITY OF CALIFORNIA AT DAVIS · PI FEREIDOUNI, FARZAD · 2020 to 2020
$92k
NIDDK NIH HHS R01 DK114485NIDDK NIH HHS R01 DK131189NIDDK NIH HHS R56 DK124873
6 · The paper itself

Abstract

Accurate quantification of renal fibrosis has profound importance in the assessment of chronic kidney disease (CKD). Visual analysis of a biopsy stained with trichrome under the microscope by a pathologist is the gold standard for evaluation of fibrosis. Trichrome helps to highlight collagen and ultimately interstitial fibrosis. However, trichrome stains are not always reproducible, can underestimate collagen content and are not sensitive to subtle fibrotic patterns. Using the Dual-mode emission and transmission (DUET) microscopy approach, it is possible to capture both brightfield and fluorescence images from the same area of a tissue stained with hematoxylin and eosin (H&E) enabling reproducible extraction of collagen with high sensitivity and specificity. Manual extraction of spectrally overlapping collagen signals from tubular epithelial cells and red blood cells is still an intensive task. We employed a UNet++ architecture for pixel-level segmentation and quantification of collagen using 760 whole slide image (WSI) patches from six cases of varying stages of fibrosis. Our trained model (Deep-DUET) used the supervised extracted collagen mask as ground truth and was able to predict the extent of collagen signal with a MSE of 0.05 in a holdout testing set while achieving an average AUC of 0.94 for predicting regions of collagen deposits. Expanding this work to the level of the WSI can greatly improve the ability of pathologists and machine learning (ML) tools to quantify the extent of renal fibrosis reproducibly and reliably.

Indexed as

Deep LearningDigital PathologyFibrosisKidney DiseaseMicroscopyWhole Slide Image

Identifiers

PMID37829619
PMCPMC10568542
OpenAlexW4362693704

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.