Evidence map›Paper›PMID 37829558›Full record

ArticleAdvanced functional materials2018

Tissue-Engineered Peripheral Nerve Interfaces.

Benjamin S Spearman, Vidhi H Desai, Sahba Mobini, Matthew D McDermott, James B Graham, Kevin J Otto, Jack W Judy, Christine E Schmidt

Open access · greenAbstract read
In one paragraph

Article in Advanced functional materials, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 44 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
44citing papers in PubMed, 1 pooled it
4.7field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

44 citing papers in PubMed, 1 synthesis or guideline pooled it, 98 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Biodegradable Medical Implants: Reshaping Future Medical Practice.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Design, Fabrication, and Implantation of Hollow Tissue-Engineered Electronic Nerve Interfaces.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2024
    Article
  11. Article
  12. Article
  13. Article
  14. Key challenges in exploring the rat as a preclinical neurostimulation model for aortic baroreflex modulation in hypertension.Hypertension research : official journal of the Japanese Society of Hypertension · 2024
    Review
  15. Review
  16. Article
  17. Article
  18. Biopolymeric Coatings for Local Release of Therapeutics from Biomedical Implants.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Review
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Benjamin S SpearmanCrayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131.
Vidhi H DesaiDepartment of Electrical and Computer Engineering, The University of Florida, 216 Larsen Hall, 116200, Gainesville, FL 32611-6200.
Sahba MobiniCrayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131.
Matthew D McDermottCrayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131.
James B GrahamCrayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131.
Kevin J OttoCrayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131.
Jack W JudyCrayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131.
Christine E SchmidtCrayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131.
University of Florida · USPurdue University West Lafayette · USUniversity of Florida Health · US

Funding

The Tissue-Engineered Electronic Nerve Interface (TEENI)R01NS111518 · NINDS · UNIVERSITY OF FLORIDA · PI JUDY, JACK W · 2019 to 2022
$2.4M
NINDS NIH HHS R01 NS111518
6 · The paper itself

Abstract

Research on neural interfaces has historically concentrated on development of systems for the brain; however, there is increasing interest in peripheral nerve interfaces (PNIs) that could provide benefit when peripheral nerve function is compromised, such as for amputees. Efforts focus on designing scalable and high-performance sensory and motor peripheral nervous system interfaces. Current PNIs face several design challenges such as undersampling of signals from the thousands of axons, nerve-fiber selectivity, and device-tissue integration. To improve PNIs, several researchers have turned to tissue engineering. Peripheral nerve tissue engineering has focused on designing regeneration scaffolds that mimic normal nerve extracellular matrix composition, provide advanced microarchitecture to stimulate cell migration, and have mechanical properties like the native nerve. By combining PNIs with tissue engineering, the goal is to promote natural axon regeneration into the devices to facilitate close contact with electrodes; in contrast, traditional PNIs rely on insertion or placement of electrodes into or around existing nerves, or do not utilize materials to actively facilitate axon regeneration. This review presents the state-of-the-art of PNIs and nerve tissue engineering, highlights recent approaches to combine neural-interface technology and tissue engineering, and addresses the remaining challenges with foreign-body response.

Indexed as

bioelectronic medicineneural interfacesneural recording and stimulationperipheral nerve regenerationsensory-motor prosthesis

Identifiers

PMID37829558
PMCPMC10569514
OpenAlexW2745427487

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked