Evidence map›Paper›PMID 37828050›Full record

ArticleCommunications biology2023

MAxSIM: multi-angle-crossing structured illumination microscopy with height-controlled mirror for 3D topological mapping of live cells.

Pedro Felipe Gardeazabal Rodriguez, Yigal Lilach, Abhijit Ambegaonkar, Teresa Vitali, Haani Jafri, Hae Won Sohn, Matthew Dalva, Susan Pierce, Inhee Chung

Open access · goldAbstract read
In one paragraph

Article in Communications biology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.7field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Pedro Felipe Gardeazabal RodriguezDepartment of Anatomy and Cell Biology, George Washington University, School of Medicine and Health Sciences, Washington, DC, USA.
Yigal LilachNanofabrication and Imaging Center, George Washington University, Washington, DC, USA.
Abhijit AmbegaonkarLaboratory of Immunogenetics, National Institute of Allergy and Infectious Disease, National Institutes of Health, Rockville, MD, USA.
Teresa VitaliDepartment of Anatomy and Cell Biology, George Washington University, School of Medicine and Health Sciences, Washington, DC, USA.
Haani JafriDepartment of Neuroscience, Thomas Jefferson University, Philadelphia, PA, USA.
Hae Won SohnLaboratory of Immunogenetics, National Institute of Allergy and Infectious Disease, National Institutes of Health, Rockville, MD, USA.
Matthew DalvaDepartment of Neuroscience, Thomas Jefferson University, Philadelphia, PA, USA.ORCID http://orcid.org/0000-0002-7737-8787
Susan PierceLaboratory of Immunogenetics, National Institute of Allergy and Infectious Disease, National Institutes of Health, Rockville, MD, USA.
Inhee ChungDepartment of Anatomy and Cell Biology, George Washington University, School of Medicine and Health Sciences, Washington, DC, USA. inheec@gwu.edu.ORCID http://orcid.org/0000-0002-2312-6357
George Washington University · USNational Institutes of Health · USThomas Jefferson University · USTulane University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Mapping 3D plasma membrane topology in live cells can bring unprecedented insights into cell biology. Widefield-based super-resolution methods such as 3D-structured illumination microscopy (3D-SIM) can achieve twice the axial ( ~ 300 nm) and lateral ( ~ 100 nm) resolution of widefield microscopy in real time in live cells. However, twice-resolution enhancement cannot sufficiently visualize nanoscale fine structures of the plasma membrane. Axial interferometry methods including fluorescence light interference contrast microscopy and its derivatives (e.g., scanning angle interference microscopy) can determine nanoscale axial locations of proteins on and near the plasma membrane. Thus, by combining super-resolution lateral imaging of 2D-SIM with axial interferometry, we developed multi-angle-crossing structured illumination microscopy (MAxSIM) to generate multiple incident angles by fast, optoelectronic creation of diffraction patterns. Axial localization accuracy can be enhanced by placing cells on a bottom glass substrate, locating a custom height-controlled mirror (HCM) at a fixed axial position above the glass substrate, and optimizing the height reconstruction algorithm for noisy experimental data. The HCM also enables imaging of both the apical and basal surfaces of a cell. MAxSIM with HCM offers high-fidelity nanoscale 3D topological mapping of cell plasma membranes with near-real-time ( ~ 0.5 Hz) imaging of live cells and 3D single-molecule tracking.

Indexed as

AlgorithmsLightingInterferometryMicroscopy, FluorescenceMicroscopy, Interference

Identifiers

PMID37828050
PMCPMC10570291
OpenAlexW4387578693

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.