Evidence map›Paper›PMID 37824548›Full record

ArticlePloS one2023

Titanium nitride coating of pectus bar increases metal contamination after minimally-invasive repair of pectus excavatum.

Caroline Fortmann, Thomas Göen, Soeren Wiesner, Jan Hegermann, Rim Kiblawi, Martha Dohna, Benno M Ure, Diane Miriam Renz, Claus Petersen, Joachim F Kuebler

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Caroline FortmannDepartment of Pediatric Surgery, Hannover Medical School, Hannover, Germany.ORCID 0000-0002-2289-5330
Thomas GöenSocial and Environmental Medicine, Institute and Outpatient Clinic of Occupational, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.ORCID 0000-0002-8226-9227
Soeren WiesnerHannover Medical School, Institute for Biostatistics, Hannover, Germany.
Jan HegermannHannover Medical School, Research Core Unit Electron Microscopy, Institute of Functional and Applied Anatomy, Hannover, Germany.
Rim KiblawiDepartment of Pediatric Surgery, Hannover Medical School, Hannover, Germany.
Martha DohnaDepartment of Pediatric Radiology, Hannover Medical School, Institute of Diagnostic and Interventional Radiology, Hannover, Germany.ORCID 0000-0002-2471-8530
Benno M UreDepartment of Pediatric Surgery, Hannover Medical School, Hannover, Germany.
Diane Miriam RenzDepartment of Pediatric Radiology, Hannover Medical School, Institute of Diagnostic and Interventional Radiology, Hannover, Germany.ORCID 0000-0002-3702-356X
Claus PetersenDepartment of Pediatric Surgery, Hannover Medical School, Hannover, Germany.
Joachim F KueblerDepartment of Pediatric Surgery, Hannover Medical School, Hannover, Germany.
Medizinische Hochschule Hannover · DEFriedrich-Alexander-Universität Erlangen-Nürnberg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionPrevious studies demonstrated a release of toxic metals, e.g. nickel and chromium, from stainless steel bars used for minimally invasive repair of pectus excavatum (MIRPE). In the present study, we investigated the impact of titanium nitride coating on the metal release and exposure of MIRPE patients. MATERIAL AND

methodsWe analyzed the courses of nickel and chromium levels in blood, urine and local tissue in patients undergoing MIRPE with a titanium nitride coated pectus bar between 03/2017 and 10/2018. Sample collection was scheduled prior to MIRPE, at defined postoperative time points and at bar removal. Additionally, we evaluated irritative symptoms. Results were compared to a control group who received uncoated stainless steel bars in a previous time period (03/2015-02/2017).

results12 patients received coated pectus bars (mean age 15.7 years). The control group included 28 patients. After implantation of a titanium nitride coated bar, significant increase in systemic nickel and chromium levels after one, two and three years was noted. In an interim analysis one year after MIRPE, we observed patients with coated bars to have significantly elevated trace metal values compared to the control group. This elevation persisted throughout the observation period. Tissue metal values were also significantly increased. Irritative symptoms occurred significantly more often in study patients compared to controls (50.0% vs. 14.3%).

conclusionsCoating of pectus bars with titanium nitride failed to reduce metal contamination after MIRPE. Instead, it resulted in a significant increase of trace metal levels after MIRPE, compared to patients with stainless steel bars, which may be explained by wear of the coating and inter-component mobilization processes.

Indexed as

Funnel ChestTrace ElementsAdolescentChromiumHumansMetalsMinimally Invasive Surgical ProceduresNickelRetrospective StudiesStainless SteelTitaniumTreatment OutcomeChromiumMetalsNickelStainless SteelTitaniumtitanium nitrideTrace Elements

Identifiers

PMID37824548
PMCPMC10569521
OpenAlexW4387569058

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.