ArticleIEEE transactions on bio-medical engineering2024
Evaluation of Robustness of S-Transform Based Phase Velocity Estimation in Viscoelastic Phantoms and Renal Transplants.
Article in IEEE transactions on bio-medical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Sound touch viscosity imaging for chronic kidney disease staging: a novel biomarker for renal fibrosis.Quantitative imaging in medicine and surgery · 2025Article
- Local phase velocity imaging with wavenumber filter banks for ultrasound shear wave elastography.Computer methods and programs in biomedicine · 2025Article
- Shear wave elastography primer for the abdominal radiologist.Abdominal radiology (New York) · 2025Review
- Twin Peak Method for Estimating Tissue Viscoelasticity Using Shear Wave Elastography.Ultrasound in medicine & biology · 2025Article
- Design and application of a realistic and multifunctional retinal phantom for standardizing ophthalmic imaging systems.Communications engineering · 2025Article
- Estimation of the phase velocity dispersion curves for viscoelastic materials using Point Limited Shear Wave Elastography.Ultrasonics · 2025Article
- Acoustic radiation force-induced longitudinal shear wave for ultrasound-based viscoelastic evaluation.Ultrasonics · 2024Article
- Ultrasound Shear Elastography With Expanded Bandwidth (USEWEB): A Novel Method for 2D Shear Phase Velocity Imaging of Soft Tissues.IEEE transactions on medical imaging · 2024Article
- Kidney cortex shear wave motion simulations based on segmented biopsy histology.Computer methods and programs in biomedicine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Ultrasound shear wave elastography (SWE) methods are being used to differentiate healthy versus diseased tissue on the basis of their viscoelastic mechanical properties. Tissue viscoelasticity is often studied by analyzing shear wave phase velocity dispersion curves, which is the variation of phase velocity with frequency or wavelength. Recently, a unique approach using a generalized Stockwell transformation (GST-SFK) was proposed for the calculation of dispersion curves in viscoelastic media over expanded frequency band. In this work, the method's robustness was evaluated on data from five custom-made viscoelastic tissue-mimicking phantoms and sixty in vivo renal transplants. For each phantom, 15 shear wave motion data acquisitions were taken, while 10-13 acquisitions were acquired for renal transplants measured in the renal cortex. For each data-set mean and standard deviation (SD) of estimated phase velocity dispersion curves were studied. In addition, the viscoelastic parameters of the Zener model were examined, which were preceded by a convergence analysis. For viscoelastic phantoms scanned with a research ultrasound scanner, and for the in vivo renal transplants scanned with a clinical scanner, the decisive advantage of the GST-SFK method over the standard two-dimensional Fourier transform (2D-FT) method was shown. The GST-SFK method provided dispersion curve estimates with lower SD over a wider frequency band in comparison to the 2D-FT method. These advantages are relevant to the analysis of the mechanical properties of tissues in clinical practice to discriminate healthy from diseased tissue.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.