ArticleActa orthopaedica et traumatologica turcica2023
Biomechanical comparison of fixation methods on third-generation femoral composite bone models in Pauwels type 3 femoral neck fractures: Contribution of the medial buttress plate to fixation.
Article in Acta orthopaedica et traumatologica turcica, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 1 citations in OpenAlex.
- Femoral neck system versus cannulated screws combined with medial plate for femoral neck fractures in young and middle-aged patients: a prospective multicenter randomized controlled trial.Journal of orthopaedic surgery and research · 2025Trial
- Biomechanical comparison of inverted triangle and L-shaped screw configurations with medial buttress and anteromedial support plate in Pauwels type III femoral neck fractures.Archives of orthopaedic and trauma surgery · 2026Article
- Biomechanical study of medial buttress plate combined with cannulated compression screws for pauwels type III femoral neck fractures using formalin-fixed human cadaveric femora.BMC musculoskeletal disorders · 2026Article
- Biomechanical comparison of locking femoral neck plate versus cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures.Acta orthopaedica et traumatologica turcica · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo compare the use of cannulated screws in an inverted triangular configuration, medial buttress plates, and the combination of these 2 fixation methods in the treatment of Pauwels type 3 femoral neck fractures.
methodsTwenty-eight anatomical composite third-generation femoral bone models were divided into 4 groups. The control group (group 1) was formed with 7 third-generation intact bone models. The fracture model was created with a 70° cutting block to fit 21 Pauwels type 3 fracture configurations. Seven models were fixed with an isolated 3.5 mm one-third semi-tubular medial buttress plate (group 2), 7 were fixed in an inverted triangular configuration with 6.5 mm cannulated screws (group 3), and 7 were fixed using a combination of 6.5 mm cannulated screws and a medial buttress plate (group 4). Cyclic loading was applied using axial forces ranging from 60 N to 600 N and moments ranging from 0.7 Nm to 7.0 Nm for 500 cycles. Once the cyclic loading stage was completed, the loads were removed from the system, and the quasi-static loading stage was employed to determine the stiffness and failure forces of the system under both axial and torsional forces. Quasi-static tests were performed with an axial speed of 1.8 mm/min and a torsional speed of 4.5°/min. The biomechanical properties of all groups were examined in terms of axial stiffness, torsional stiffness, and maximum axial force parameters.
resultsThe stiffness values of groups 1, 2, 3, and 4 were 303 ± 35.8 N/mm, 159.6 ± 25 N/mm, 232 ± 35.9 N/mm, and 366.9 ± 58 N/mm, respectively, under axial forces (P < .01); 2172.7 ± 252.1 Nmm/°, 1225.3 ± 238.6 Nmm/°, 2123 ± 359.4 Nmm/°, and 2721.85 ± 304 Nmm/°, respectively, under torsional moments (P < .01); and 2072.1 ± 256.1 N, 1379.9 ± 290.6 N, 2099.1 ± 454.2 N, and 2648.4 ± 364.6 N, respectively, under the maximum force (P < .01).
conclusionThis study showed that in the fixation of Pauwels type 3 fractures formed on third-generation bone models, the utilization of half-thread cannulated screws in an inverted triangle configuration, along with a medial buttress plate, provided stronger fixation compared to the remaining implant groups and the control group. According to the evaluation of the parameters, the isolated application of a medial buttress plate had poorer biomechanical properties than other fixation methods.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.