ArticlePhysics in medicine and biology2023
Radiation-induced acoustic signal denoising using a supervised deep learning framework for imaging and therapy monitoring.
Article in Physics in medicine and biology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Recent advances in applying machine learning to proton radiotherapy.Biomedical physics & engineering express · 2025Pooled it
- A single-view-based electroacoustic tomography imaging using deep learning for electroporation monitoring.Medical physics · 2026Article
- Limited-view signal recovery with frequency-aware denoising diffusion and geometry-integrated masked autoencoders for X-ray acoustic computed tomography.Photoacoustics · 2026Article
- Seeing the invisible: In vivo dosimetry in radiotherapy with radiacoustic IMAGING.Medical physics · 2025Review
- X-ray-induced acoustic computed tomography: 3D X-ray absorption imaging from a single view.Science advances · 2024Article
- Toward real-time, volumetric dosimetry for FLASH-capable clinical synchrocyclotrons using protoacoustic imaging.Medical physics · 2024Article
- 4DPhysics in medicine and biology · 2024Article
- Real-time tracking of the Bragg peak during proton therapy via 3D protoacoustic Imaging in a clinical scenario.Npj imaging · 2024Article
- X-ray-induced acoustic computed tomography and its applications in biomedicine.Journal of biomedical optics · 2024Review
Corrections and comments
- Update of
Authors and funding
9 authors.
Funding
Abstract
Radiation-induced acoustic (RA) imaging is a promising technique for visualizing the invisible radiation energy deposition in tissues, enabling new imaging modalities and real-time therapy monitoring. However, RA imaging signal often suffers from poor signal-to-noise ratios (SNRs), thus requiring measuring hundreds or even thousands of frames for averaging to achieve satisfactory quality. This repetitive measurement increases ionizing radiation dose and degrades the temporal resolution of RA imaging, limiting its clinical utility. In this study, we developed a general deep inception convolutional neural network (GDI-CNN) to denoise RA signals to substantially reduce the number of frames needed for averaging. The network employs convolutions with multiple dilations in each inception block, allowing it to encode and decode signal features with varying temporal characteristics. This design generalizes GDI-CNN to denoise acoustic signals resulting from different radiation sources. The performance of the proposed method was evaluated using experimental data of x-ray-induced acoustic, protoacoustic, and electroacoustic signals both qualitatively and quantitatively. Results demonstrated the effectiveness of GDI-CNN: it achieved x-ray-induced acoustic image quality comparable to 750-frame-averaged results using only 10-frame-averaged measurements, reducing the imaging dose of x-ray-acoustic computed tomography (XACT) by 98.7%; it realized proton range accuracy parallel to 1500-frame-averaged results using only 20-frame-averaged measurements, improving the range verification frequency in proton therapy from 0.5 to 37.5 Hz; it reached electroacoustic image quality comparable to 750-frame-averaged results using only a single frame signal, increasing the electric field monitoring frequency from 1 fps to 1k fps. Compared to lowpass filter-based denoising, the proposed method demonstrated considerably lower mean-squared-errors, higher peak-SNR, and higher structural similarities with respect to the corresponding high-frame-averaged measurements. The proposed deep learning-based denoising framework is a generalized method for few-frame-averaged acoustic signal denoising, which significantly improves the RA imaging's clinical utilities for low-dose imaging and real-time therapy monitoring.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials