Evidence map›Paper›PMID 37817822›Full record

ArticleIEEE journal of translational engineering in health and medicine2023

Design and Evaluation of a Balanced Compliant Laparoscopic Grasper.

Jan-Willem Klok, Roelf Postema, Aspor T Steinporsson, Jenny Dankelman, Tim Horeman

Open access · goldAbstract read
In one paragraph

Article in IEEE journal of translational engineering in health and medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. A Hybrid Compliant-Tendon Laparoscopic Instrument for Distal Articulation and Grasping: Design and Experimental Validation.The international journal of medical robotics + computer assisted surgery : MRCAS · 2026
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Jan-Willem KlokDepartment of Biomechanical EngineeringDelft University of Technology 2628 CD Delft The Netherlands.ORCID 0000-0003-3868-2046
Roelf PostemaSpijkenisse Medisch Centrum 3201 GZ Spijkenisse The Netherlands.ORCID 0000-0003-1502-0904
Aspor T SteinporssonReon 105 Reykjavik Iceland.
Jenny DankelmanDepartment of Biomechanical EngineeringDelft University of Technology 2628 CD Delft The Netherlands.ORCID 0000-0003-3951-2129
Tim HoremanDepartment of Biomechanical EngineeringDelft University of Technology 2628 CD Delft The Netherlands.ORCID 0000-0002-8527-4486
Delft University of Technology · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In laparoscopic surgery, quality of haptic feedback is reduced compared to conventional surgery, leading to unintentional tissue damage during grasping. From the perspective of haptics, poor mechanical design of laparoscopic instrument joints induces friction and a nonlinear actuation-tip force relation. In this study, a novel laparoscopic grasper using compliant joints and a magnetic balancer is presented, and the reduction in hysteresis and friction is evaluated. The hysteresis loop of the novel compliant grasper and two conventional laparoscopic graspers (high quality leading commercial brand and low quality unbranded grasper) were measured. In order to assess quality of haptic feedback, the lowest grasper tip load perceivable by instrument users was measured with the novel and the conventional laparoscopic graspers. The hysteresis loop measurement yielded a mechanical efficiency of 43% for the novel grasper, compared to- 25% and 23% for the Aesculap and the unbranded grasper, respectively. The forces perceivable by the user through the novel grasper were significantly lower (mean 1.37N, SD 0.44N) than those of conventional graspers (mean 2.15N, SD 0.71N and mean 2.65N, SD 1.20N, respectively). The balanced compliant grasper technology has the ability to improve the quality of haptic feedback compared to conventional laparoscopic graspers. Research is needed to relate these results to soft and delicate tissue grasping in a clinical setting, for which this instrument is intended.

Indexed as

LaparoscopyEquipment DesignFeedbackFrictionHand Strengthcompliant mechanismsgraspinghaptic feedbackLaparoscopic surgerystatic balancing

Identifiers

PMID37817822
PMCPMC10561751
OpenAlexW4382998647

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked