ArticlePloS one2023
Open acid dissolution-Ammonia solution extraction-ICP OES rapid determination of 7 trace metal elements in soil.
Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To overcome the corrosion of hydrofluoric acid on the ICP OES injection system in the acid dissolution system, this paper makes some improvements based on the traditional open digestion. The improved method does not require the complete removal of hydrofluoric acid. After appropriate digestion of the sample with a mixed acid, the solution can be transferred to a colorimetric tube containing ammonium hydroxide solution to give the final volume for analysis. In this paper, two-point standard curves are plotted using soil standards and process blanks, which is not only convenient but also overcomes the interference of the matrix effect. Through continuous experiments, the preferred ratio of mixed acid is 3 mL nitric acid + 5 mL hydrofluoric acid, and the concentration of ammonia solution is 0.5%. The spectral lines of the measured elements V (292.4), Cr (283.5), Co (228.6), Ni (231.6), Cu (324.7), Zn (213.8) and Pb (220.3) were determined. The method quantification limits of the seven measured elements V, Cr, Co, Ni, Cu, Zn and Pb were 0.909, 4.32, 0.269, 0.261, 0.968, 3.69 and 2.64 μg g-1, respectively, and the precision was 3.5%, 5.2%, 4.8%, 2.4%, 6.1% and 4.5%, respectively. After processing six national standard materials according to the experimental method, the measured values of each measured element were basically in agreement with the certified values, indicating that this method is fully feasible for the measurement of V, Cr, Co, Ni, Cu, Zn and Pb in soil. This method greatly improves the efficiency of pretreatment and is particularly suitable for analysing large batches of samples.