ArticleJournal of synchrotron radiation2023
Passive doubly curved structures for determining clamping forces applied to X-ray optic assemblies.
Article in Journal of synchrotron radiation, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Clamping of indirectly cryogenically cooled X-ray optics is required to ensure effective heat transfer between the optic and heat exchanger. However, clamping forces can result in distortion of the optical surface of monochromators and mirror systems, which causes angular distortions of the subsequent beam. As such, there is a need for greater understanding of how these optics are assembled and how this affects their performance throughout their life cycle. In this paper, the potential for non-contact, in-process monitoring of the clamping force both during and after assembly using an additively manufactured passive structure based on a doubly curved hyperbolic paraboloid and designed for application to the first crystal for the I20 monochromator at Diamond Light Source is investigated numerically and experimentally. The performance of the passive structure both pre- and post-cryogenic quenching is characterized experimentally. Laser displacement measurements reveal approximately 9 µm total displacement in the passive structure per 100 N of bolt preload, corresponding to an effective magnification of the preload adjustment of approximately 2.5×.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.