Evidence map›Paper›PMID 37815020›Full record

ArticleMagnetic resonance in medicine2024

Real-time water/fat imaging at 0.55T with spiral out-in-out-in sampling.

Ye Tian, Krishna S Nayak

Open access · hybridAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.8field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Simultaneous multi-slice cardiac real-time MRI at 0.55T.Magnetic resonance in medicine · 2025
    Article
  7. Article
  8. Article
  9. Review
  10. Assessment of MRF for simultaneous TMagma (New York, N.Y.) · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Ye TianMing Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA.ORCID 0000-0002-8559-4404
Krishna S NayakMing Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA.ORCID 0000-0001-5735-3550
University of Southern California · US

Funding

Novel Myocardial Perfusion Stress Test using Arterial Spin LabelingR01HL130494 · NHLBI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI NAYAK, KRISHNA S · 2016 to 2019
$1.7M
Improved Myocardial Perfusion Assessment using High-Performance Low-Field MRIR21HL159533 · NHLBI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI NAYAK, KRISHNA S · 2022 to 2023
$454k
NHLBI NIH HHS R01 HL130494NHLBI NIH HHS R21 HL159533NIH HHS R01-HL130494NIH HHS R21-HL159533
6 · The paper itself

Abstract

purposeTo develop an efficient and flexible water/fat separated real-time MRI (RT-MRI) method using spiral out-in-out-in (OIOI) sampling and balanced SSFP (bSSFP) at 0.55T.

methodsA bSSFP sequence with golden-angle spiral OIOI readout was developed, capturing three echoes to allow water/fat separation. A low-latency reconstruction that combines all echoes was available for online visualization. An offline reconstruction provided water and fat RT-MRI in two steps: (1) image reconstruction with spatiotemporally constrained reconstruction (STCR) and (2) water/fat separation with hierarchical iterative decomposition of water and fat with echo asymmetry and least-squares estimation (HIDEAL). In healthy volunteers, spiral OIOI was acquired in the wrist during a radial-to-ulnar deviation maneuver, in the heart without breath-hold and cardiac gating, and in the lower abdomen during free-breathing for visualizing small bowel motility.

resultsWe demonstrate successful water/fat separated RT-MRI for all tested applications. In the wrist, resulting images provided clear depiction of ligament gaps and their interactions during the radial-to-ulnar deviation maneuver. In the heart, water/fat RT-MRI depicted epicardial fat, provided improved delineation of epicardial coronary arteries, and provided high blood-myocardial contrast for ventricular function assessment. In the abdomen, water-only RT-MRI captured small bowel mobility clearly with improved water-fat contrast.

conclusionsWe have demonstrated a novel and flexible bSSFP spiral OIOI sequence at 0.55T that can provide water/fat separated RT-MRI with a variety of application-specific temporal resolution and spatial resolution requirements.

Indexed as

Image Interpretation, Computer-AssistedWaterHeartHumansMagnetic Resonance ImagingRespirationWater0.55 Teslareal-time MRIspiral out-in-out-inwater/fat separation

Identifiers

PMID37815020
PMCPMC10841523
OpenAlexW4387473017

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.