Evidence map›Paper›PMID 37814682›Full record

ArticleBioinformation2023

Implant abutment using hand drivers versus torque wrench.

Himani Singh, Subhash Sonkesriya, Bhumika J Patel, Varsha Rathod, Bharat Gupta, Tarun Vyas, Anshul Sawhney, Ramanpal Singh Makkad

Open access · hybridAbstract read
In one paragraph

Article in Bioinformation, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Himani SinghDepartment of Oral Medicine and Radiology, Kothiwal Dental College and Research Centre, Moradabad, Uttar Pradesh, India.
Subhash SonkesriyaDepartment of Prosthodontics, Government College of Dentistry, Indore, M.P., India.
Bhumika J PatelDepartment of Oral Medicine and Radiology, Gujarat, India.
Varsha RathodDepartment of Periodontology, Bharati Vidyapeeth Dental College and Hospital, Navi Mumbai, India.
Bharat GuptaDepartment of Periodontology, MGM Dental College, Navi Mumbai, India.
Tarun VyasDepartment of Oral Medicine and Radiology, Vyas Dental College and Hospital, Jodhpur, Rajasthan, India.
Anshul SawhneyDepartment of Dentistry, MSDASMC Bahraich, India.
Ramanpal Singh MakkadDepartment of Oral Medicine and Radiology, New Horizon Dental college and Research institute, Bilaspur, Chhattisgarh, India.
Kothiwal Dental College and Research Centre · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The most frequent instrument used to begin tightening screws is a manually regulated screwdriver. Regarding manually regulated screwdrivers, predicted margins of error vary between fifteen percent to forty eight percent. Mechanical Torque restricting devices can consistently produce the requisite torques. As a result, devices like wrenches are needed to achieve the desirable values of torque. Hence, the present study was designed to evaluate the torque difference between handheld drivers and torque wrench and thereby its effect on the internal threads of implant surface.120 blocks was prepared from an autopolymerizing type of acrylic material each with a dimension of 1 inch. The centre of each block was affixed with analogue of dental impalnts with dimensions of 3.5 mm width and 13 mm length. With 60 specimens each, these models were split into two categories: hand torque specimens category and torque wrench specimens category. A stereomicroscope was used to look at the implant analog's internal threading architecture at a magnification of 100. At the bottom and top, four threads were spaced apart by a certain amount. Biowizard software was used for the assessment, and the results were recorded. Threads on the internal surface of dental implants were produced once more following torquing the implant's impression, and the stereomicroscope was used to quantify the separation between the 4 threads. Statistics were used to correlate the readings. All study participants' hand torque as well as torque wrench measurements were documented and statistical analysis was performed on them. When there was statistical analysis of the measurements then it was observed that mean values of torque in specimens included category of manual torque application was found out to be 33.6 ± 6.510 Ncm. On the other hand the mean values of torque in specimens included in category of torque application by torque wrench were found out to be 33.57 ± 3.472 Ncm. The outcome showed operator heterogeneity for both categories and operator variance when using a manual driver to generate torque. One independent - sample t test was used to contrast the mean data between the two categories, and P< 0.05 was chosen to determine whether the intergroup difference was meaningful. Because the torque values obtained with hand tightening were uneven, it may be concluded that different levels of hand torquing skill caused the torque to fluctuate. The torque wrench device displayed the desired torque data in the range that the manufacturer had advised. However, utilising manual drivers and a mechanical torque instrument did not cause any modifications to thread on the internal surface, and it rarely underwent significant deformation during the preliminary tightening torque readings. Thus, given that manually hand regulated drivers create a range of torques, it may be inferred that the employment of mechanical torque restricting instruments should be required.

Indexed as

abutment screwDental implantshand driversinternal threadtorque wrench

Identifiers

PMID37814682
PMCPMC10560308
OpenAlexW4360985092

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.