ArticleBMC medical informatics and decision making2023
Machine learning clinical prediction models for acute kidney injury: the impact of baseline creatinine on prediction efficacy.
Article in BMC medical informatics and decision making, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 16 citations in OpenAlex.
- Association between HALP score and in-hospital outcomes in patients with acute kidney injury: a retrospective cohort study.Scientific reports · 2026Article
- Prediction of acute kidney injury in patients with acute pesticide poisoning using the PKIP score.Scientific reports · 2026Article
- CRISP: A causal relationships-guided deep learning framework for advanced ICU mortality prediction.BMC medical informatics and decision making · 2025Article
- Machine Learning to Assist in Managing Acute Kidney Injury in General Wards: Multicenter Retrospective Study.Journal of medical Internet research · 2025Article
- An effective multi-step feature selection framework for clinical outcome prediction using electronic medical records.BMC medical informatics and decision making · 2025Article
- Machine learning approaches toward an understanding of acute kidney injury: current trends and future directions.The Korean journal of internal medicine · 2024Review
- Artificial intelligence and machine learning's role in sepsis-associated acute kidney injury.Kidney research and clinical practice · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThere are many Machine Learning (ML) models which predict acute kidney injury (AKI) for hospitalised patients. While a primary goal of these models is to support clinical decision-making, the adoption of inconsistent methods of estimating baseline serum creatinine (sCr) may result in a poor understanding of these models' effectiveness in clinical practice. Until now, the performance of such models with different baselines has not been compared on a single dataset. Additionally, AKI prediction models are known to have a high rate of false positive (FP) events regardless of baseline methods. This warrants further exploration of FP events to provide insight into potential underlying reasons.
objectiveThe first aim of this study was to assess the variance in performance of ML models using three methods of baseline sCr on a retrospective dataset. The second aim was to conduct an error analysis to gain insight into the underlying factors contributing to FP events. MATERIALS AND
methodsThe Intensive Care Unit (ICU) patients of the Medical Information Mart for Intensive Care (MIMIC)-IV dataset was used with the KDIGO (Kidney Disease Improving Global Outcome) definition to identify AKI episodes. Three different methods of estimating baseline sCr were defined as (1) the minimum sCr, (2) the Modification of Diet in Renal Disease (MDRD) equation and the minimum sCr and (3) the MDRD equation and the mean of preadmission sCr. For the first aim of this study, a suite of ML models was developed for each baseline and the performance of the models was assessed. An analysis of variance was performed to assess the significant difference between eXtreme Gradient Boosting (XGB) models across all baselines. To address the second aim, Explainable AI (XAI) methods were used to analyse the XGB errors with Baseline 3.
resultsRegarding the first aim, we observed variances in discriminative metrics and calibration errors of ML models when different baseline methods were adopted. Using Baseline 1 resulted in a 14% reduction in the f1 score for both Baseline 2 and Baseline 3. There was no significant difference observed in the results between Baseline 2 and Baseline 3. For the second aim, the FP cohort was analysed using the XAI methods which led to relabelling data with the mean of sCr in 180 to 0 days pre-ICU as the preferred sCr baseline method. The XGB model using this relabelled data achieved an AUC of 0.85, recall of 0.63, precision of 0.54 and f1 score of 0.58. The cohort size was 31,586 admissions, of which 5,473 (17.32%) had AKI.
conclusionIn the absence of a widely accepted method of baseline sCr, AKI prediction studies need to consider the impact of different baseline methods on the effectiveness of ML models and their potential implications in real-world implementations. The utilisation of XAI methods can be effective in providing insight into the occurrence of prediction errors. This can potentially augment the success rate of ML implementation in routine care.