Evidence map›Paper›PMID 37813917›Full record

ArticleScientific reports2023

Setup accuracy and margins for surface-guided radiotherapy (SGRT) of head, thorax, abdomen, and pelvic target volumes.

Volker Rudat, Yanyan Shi, Ruping Zhao, Shuyin Xu, Wei Yu

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed
6.8field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Multiregional assessment of surface guidance for patient positioning in radiotherapy.Technical innovations & patient support in radiation oncology · 2026
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Volker RudatDepartment of Radiation Oncology, Jiahui International Cancer Center Shanghai, Jiahui Health, Shanghai, China. volker.rudat@gmail.com.
Yanyan ShiDepartment of Radiation Oncology, Jiahui International Cancer Center Shanghai, Jiahui Health, Shanghai, China.
Ruping ZhaoDepartment of Radiation Oncology, Jiahui International Cancer Center Shanghai, Jiahui Health, Shanghai, China.
Shuyin XuDepartment of Radiation Oncology, Jiahui International Cancer Center Shanghai, Jiahui Health, Shanghai, China.
Wei YuDepartment of Radiation Oncology, Jiahui International Cancer Center Shanghai, Jiahui Health, Shanghai, China.
Shanghai Cancer Institute · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The goal of the study was to evaluate the inter- and intrafractional patient setup accuracy of target volumes located in the head, thoracic, abdominal, and pelvic regions when using SGRT, by comparing it with that of laser alignment using patient skin marks, and to calculate the corresponding setup margins. A total of 2303 radiotherapy fractions of 183 patients were analyzed. All patients received daily kilovoltage cone-beam computed tomography scans (kV-CBCT) for online verification. From November 2019 until September 2020, patient setup was performed using laser alignment with patient skin marks, and since October 2020, using SGRT. The setup accuracy was measured by the six degrees of freedom (6DOF) corrections based on the kV-CBCT. The corresponding setup margins were calculated using the van Herk formula. Analysis of variance (ANOVA) was used to evaluate the impact of multiple factors on the setup accuracy. The inter-fractional patient setup accuracy was significantly better using SGRT compared to laser alignment with skin marks. The mean three-dimensional vector of the translational setup deviation of tumors located in the thorax, abdomen, and pelvis using SGRT was 3.6 mm (95% confidence interval (CI) 3.3 mm to 3.9 mm) and 4.5 mm using laser alignment with skin marks (95% CI 3.9 mm to 5.2 mm; p = 0.001). Calculation of setup margins for the combined inter- and intra-fractional setup error revealed similar setup margins using SGRT and kV-CBCT once a week compared to laser alignment with skin marks and kV-CBCT every other day. Furthermore, comparable setup margins were found for open-face thermoplastic masks with AlignRT compared to closed-face thermoplastic masks with laser alignment and mask marks. SGRT opens the possibility to reduce the number of CBCTs while maintaining sufficient setup accuracy. The advantage is a reduction of imaging dose and overall treatment time. Open-face thermoplastic masks may be used instead of closed-face thermoplastic masks to increase the patient's comfort.

Indexed as

Radiotherapy, Image-GuidedAbdomenCone-Beam Computed TomographyHumansPatient PositioningPelvisRadiotherapy Planning, Computer-AssistedRadiotherapy Setup ErrorsThorax

Identifiers

PMID37813917
PMCPMC10562432
OpenAlexW4387451415

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.