Evidence map›Paper›PMID 37812307›Full record

ArticleOphthalmology and therapy2023

Fluid Supplementation Through Weakened Zonules via Side-Port Incision to Maintain Intraocular Pressure in High Myopic Eyes.

Dandan Wang, Jingyi Shi, Weichen Guan, Minying Zhu, Xicong Lou, Yinying Zhao, Pingjun Chang, Yune Zhao

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Ophthalmology and therapy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05201677 (Improved Operation of Low Intraocular Pressure in Phacoemulsification for Patients With High Myopia Complicated With Cataract), which is not on this map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05201677 naunknown statusnot on this map

Improved Operation of Low Intraocular Pressure in Phacoemulsification for Patients With High Myopia Complicated With Cataract

TypeinterventionalSponsorYune ZhaoRan2021 to 2022Enrolled60ConditionsHigh Myopia, Low Intraocular PressureArmsSupplement of perfusion fluid through the subiris suspensory ligament space from the lateral incision
3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Dandan Wang *Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325000, Zhejiang, China.
Jingyi Shi *Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325000, Zhejiang, China.
Weichen GuanEye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325000, Zhejiang, China.
Minying ZhuEye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325000, Zhejiang, China.
Xicong LouEye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325000, Zhejiang, China.
Yinying ZhaoEye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325000, Zhejiang, China.
Pingjun ChangEye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325000, Zhejiang, China.
Yune ZhaoEye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325000, Zhejiang, China. zye@eye.ac.cn.ORCID http://orcid.org/0000-0003-4401-8053
Wenzhou Medical University · CN

Funding

Pioneer and Leading Goose Project of Zhejiang province 2022C03070
6 · The paper itself

Abstract

introductionDuring phacoemulsification, the infusion pressure can cause the liquefied vitreous fluid to escape through the ciliary fiber interspace in highly myopic eyes, leading to reduced vitreous cavity pressure similar to vitrectomized eyes. This study assessed the probability of low intraocular pressure (IOP) in high myopic eyes with different axial length (AL) group undergoing cataract surgery, as well as the impact of balanced salt solution (BSS) supplementation and the optimal IOP value for such supplementation.

methodsThe control group consisted of cataract eyes with normal AL (group 1: 22 mm ≤ AL < 24.5 mm), while cataract eyes with high axial myopia were categorized into three groups (group 2: 26 mm ≤ AL < 28 mm, group 3: 28 mm ≤ AL < 30 mm, group 4: AL ≥ 30 mm). IOP was measured using the iCare pro tonometer intraoperatively. BSS supplementation was performed to raise IOP in cases of low IOP, before intraocular lens (IOL) implantation and before the end of surgery. The probability of low IOP was calculated, and the IOP before and after supplementation were compared.

resultsNinety-five eyes were included. The total probability of low IOP in groups 2, 3, and 4 was 56.52, 62.50, and 70.83%, respectively, significantly higher than that in group 1 (16.67%). Similarly, the probability of low IOP before IOL implantation was significantly higher in groups 2, 3, 4 (43.48, 41.67, and 62.50%) compared to group 1 (4.17%, P < 0.05). The IOP before and after the first BSS supplementation in three high myopia groups were statistically significant (P < 0.05), increasing from 12.10 mmHg (range, 6.0-24.9 mmHg) to 16.60 mmHg (range, 10.2-34.4 mmHg). After the second BSS supplementation before the end of surgery, the IOP of high myopia groups increased from 12.60 mmHg (range, 7.0-25.3 mmHg) to 14.60 mmHg (range, 9.8-25.3 mmHg).

conclusionsThe condition of highly myopic eyes seems more likely to develop low IOP during cataract surgery. There is an observed correlation: as AL increases, the total probability of low IOP rises. In patients with IOP < 9.5 mmHg intraoperatively, fluid supplementation via a side-port incision can effectively raise IOP to about 16 mmHg before IOL implantation and about 14 mmHg after incision sealing, facilitating smoother IOL implantation and reducing the risk of postoperative low IOP.

trial registrationNCT, NCT05201677. Registered 23 November 2021-Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT05201677 .

Indexed as

Cataract surgeryHighly myopic eyesLow intraocular pressureThe pressure of vitreous cavity

Identifiers

PMID37812307
PMCPMC10640526
OpenAlexW4387439907

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.