Evidence map›Paper›PMID 37811500›Full record

ArticleClinics in orthopedic surgery2023

Accuracy of Patient-Specific Instrument for Cylindrical Axis Implementation in Kinematically Aligned Total Knee Arthroplasty.

Kwang-Kyoun Kim, Jaehwang Song

Open access · diamondAbstract read
In one paragraph

Article in Clinics in orthopedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Preoperative three-dimensional simulation and clinical evaluation ofQuantitative imaging in medicine and surgery · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Kwang-Kyoun KimDepartment of Orthopedic Surgery, Konyang University College of Medicine, Daejeon, Korea.ORCID https://orcid.org/0000-0002-6844-5431
Jaehwang SongDepartment of Orthopedic Surgery, Konyang University College of Medicine, Daejeon, Korea.ORCID https://orcid.org/0000-0001-5192-4965
Konyang University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: In kinematically aligned total knee arthroplasty (KA-TKA), the cylindrical axis (CA) is very important in restoring the native joint line and kinematics of the pre-arthritic knee. This study aimed to determine the accuracy of patient-specific instrument (PSI) for restoring the CA for femoral bone resection in KA-TKA. Methods: Thirty KA-TKAs were performed using a computed tomography (CT)-based PSI system. Data from preoperative CT were reconstructed into three-dimensional (3D) models using 3D-planning software. The CA was created by connecting the centers of each virtual sphere to the medial and lateral femoral condyles using computer software. Femoral bone resection of the distal and posterior condyles was performed parallel to the sagittal planes of the CA. The thickness of the CA-referenced bone resection was determined based on the thickness necessary for the respective regions of the femoral component. The PSI was manufactured to locate the guide pin for a conventional cutting block. The accuracy of PSI for KA-TKA was evaluated as the absolute error between the preoperatively predicted thickness and the intraoperative measurements in each of the four regions, as well as the difference in error between distal-medial (DM) and posterior-medial (PM) and between distal-lateral (DL) and posterior-lateral (PL). Results: The differences in thickness of bone cut in the DM, DL, PM, and PL were 0.79 ± 0.39 mm (range, -1.20 to 1.50), 0.70 ± 0.42 mm (range, -1.50 to 1.50), 0.80 ± 0.46 mm (range, -0.80 to 1.50), and 0.75 ± 0.47 mm (range, -2.10 to 1.40), respectively. There was no significant difference in the thickness error between DM and PM ( Conclusions: In KA-TKA, PSI was effective for accurate femoral bone resection based on virtually planned thickness.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeBiomechanical PhenomenaFemurHumansKnee JointComputer-assisted surgeryKinematic alignmentPatient-specific instrumentTotal knee arthroplasty

Identifiers

PMID37811500
PMCPMC10551691
OpenAlexW4312934957

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.