ArticleClinics in orthopedic surgery2023
Accuracy of Patient-Specific Instrument for Cylindrical Axis Implementation in Kinematically Aligned Total Knee Arthroplasty.
Article in Clinics in orthopedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 6 citations in OpenAlex.
- VELYS robotic-assisted solution achieves more accurate bone cutting and neutral ground mechanical axis compared with an accelerometer-based portable navigation system in ground kinematically aligned total knee arthroplasty.Knee surgery & related research · 2026Article
- High bilateral bony symmetry in dysplastic and nondysplastic knees: a CT-based 3D evaluation.BMC musculoskeletal disorders · 2025Article
- Comparison of a patient-specific instrument and conventional high tibial Osteotomy: Accuracy of correction target and prevention of posterior tibial slope change.Asia-Pacific journal of sports medicine, arthroscopy, rehabilitation and technology · 2025Article
- Femoral resection accuracy and precision in manual caliper-verified kinematic alignment total knee arthroplasty.Journal of experimental orthopaedics · 2025Article
- Preoperative three-dimensional simulation and clinical evaluation ofQuantitative imaging in medicine and surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: In kinematically aligned total knee arthroplasty (KA-TKA), the cylindrical axis (CA) is very important in restoring the native joint line and kinematics of the pre-arthritic knee. This study aimed to determine the accuracy of patient-specific instrument (PSI) for restoring the CA for femoral bone resection in KA-TKA. Methods: Thirty KA-TKAs were performed using a computed tomography (CT)-based PSI system. Data from preoperative CT were reconstructed into three-dimensional (3D) models using 3D-planning software. The CA was created by connecting the centers of each virtual sphere to the medial and lateral femoral condyles using computer software. Femoral bone resection of the distal and posterior condyles was performed parallel to the sagittal planes of the CA. The thickness of the CA-referenced bone resection was determined based on the thickness necessary for the respective regions of the femoral component. The PSI was manufactured to locate the guide pin for a conventional cutting block. The accuracy of PSI for KA-TKA was evaluated as the absolute error between the preoperatively predicted thickness and the intraoperative measurements in each of the four regions, as well as the difference in error between distal-medial (DM) and posterior-medial (PM) and between distal-lateral (DL) and posterior-lateral (PL). Results: The differences in thickness of bone cut in the DM, DL, PM, and PL were 0.79 ± 0.39 mm (range, -1.20 to 1.50), 0.70 ± 0.42 mm (range, -1.50 to 1.50), 0.80 ± 0.46 mm (range, -0.80 to 1.50), and 0.75 ± 0.47 mm (range, -2.10 to 1.40), respectively. There was no significant difference in the thickness error between DM and PM ( Conclusions: In KA-TKA, PSI was effective for accurate femoral bone resection based on virtually planned thickness.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.