Evidence map›Paper›PMID 37809838›Full record

ArticleHeliyon2023

Arthroscopic knots: Suture and knot characterisation of modern polyblend suture materials.

Earle Savage, Christopher J Hurren, Gayathri Devi Rajmohan, William Thomas, Richard S Page

Abstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. [Applications and challenges of ultra-high molecular weight polyethylene fibers in minimally invasive medical devices].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026
    Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Earle SavageBarwon Centre of Orthopaedic Research and Education, Barwon Health and St John of God Hospital, Geelong, Australia.
Christopher J HurrenDeakin University, Institute for Frontier Materials, Geelong, Australia.
Gayathri Devi RajmohanDeakin University, Institute for Frontier Materials, Geelong, Australia.
William ThomasRoyal Devon & Exeter Hospital, Devon, UK.
Richard S PageBarwon Centre of Orthopaedic Research and Education, Barwon Health and St John of God Hospital, Geelong, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: The primary aim of this study was to explore the relationship between the biophysical structure and function of modern suture materials. Particularly the suture's ability to withstand the stressors of surgery and how the material properties affect knot stability. The secondary aim was to investigate the effect that different knots have on the suture material itself. This study builds on previous research assessing suture and knot characteristics but in modern Ultra High Molecular Weight Polyethylene (UHMWPE) materials currently in widespread clinical use in arthroscopic surgery. Methods: Three common UHMWPE sutures and one polyester suture were tested in both a dry and wet state using the Geelong, Nicky's, Surgeon's and Tautline knots. Tensile strength of knots was tested vertically at a 60 mm/min strain rate and 45 mm gauge length. Sutures were tied through a cannula around two 8 mm diameter circular bollards. Testing was conducted in a controlled environment temperature and humidity environment (20 ± 2 °C, 65 ± 2%). Results: No one knot type was optimal over all suture types. Mean tensile strength in both a dry and wet state and a low coefficient of variation (CV) in tensile strength in a wet state were considered as an indication of suitability. With Ethibond sutures this was the Geelong knot (CV:4.2%). With Orthocord sutures both the Geelong and Tautline knots (CV:4.2% and CV:11.9% respectively). With FiberWire sutures the Nickys and Tautline knots (CV:22.6% and CV:22.5% respectively). With ForceFiber sutures all four knots exhibited similar wet tensile strength with high variability showing that all should perform in a similar way Conclusions: This study demonstrates a statistically significant three-way interaction between polyblend suture materials, the knot and the environment. This has implications for knot security using the tested sutures in different environments, as one knot may not behave the same under all conditions.

Indexed as

Arthroscopic knots characterisationContemporary UHMWPE sutureKnotsSuture and knot characterisation and orthopaedic surgeryTensile strength of knots

Identifiers

PMID37809838
PMCPMC10558336

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.