Evidence map›Paper›PMID 37805976›Full record

ArticleJournal of neurology2024

Effects of pupil size in video head-impulse tests.

Ho-Jin Yoon, Jeong-Heon Lee, Joo-Hyeong Lee, Euyhyun Park, Sun-Uk Lee, Byung-Jo Kim, Ji-Soo Kim

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of neurology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.9field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. CardiacClinical autonomic research : official journal of the Clinical Autonomic Research Society · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Ho-Jin YoonDepartment of Neurology, Korea University Medical Center, 73 Goryeodae-ro, Seongbuk-gu, Seoul, 02841, South Korea.
Jeong-Heon LeeDepartment of Neurology, Korea University Medical Center, 73 Goryeodae-ro, Seongbuk-gu, Seoul, 02841, South Korea.
Joo-Hyeong LeeDepartment of Neurology, Korea University Medical Center, 73 Goryeodae-ro, Seongbuk-gu, Seoul, 02841, South Korea.
Euyhyun ParkNeurotology and Neuro-Ophthalmology Laboratory, Korea University Anam Hospital, Seoul, South Korea.
Sun-Uk LeeDepartment of Neurology, Korea University Medical Center, 73 Goryeodae-ro, Seongbuk-gu, Seoul, 02841, South Korea. sulee716@gmail.com.ORCID http://orcid.org/0000-0001-8660-7759
Byung-Jo KimDepartment of Neurology, Korea University Medical Center, 73 Goryeodae-ro, Seongbuk-gu, Seoul, 02841, South Korea.
Ji-Soo KimDepartment of Neurology, Seoul National University College of Medicine, Seoul, South Korea.
Korea University · KRKorea University Medical Center · KRSeoul National University · KR

Funding

Ministry of Science and ICT, South Korea 2022R1A4A1018869
6 · The paper itself

Abstract

The results of video head impulse tests (video-HITs) may be confounded by data artifacts of various origins, including pupil size and eyelid obstruction of the pupil. This study aimed to determine the effect of these factors on the results of video-HITs. We simulated ptosis by adopting pharmacological dilatation of the pupil in 21 healthy participants (11 women; age 24-58 years). Each participant underwent video-HITs before and after pupillary dilatation using 0.5% tropicamide. We assessed the changes in the vestibulo-ocular reflex (VOR) gain, corrective saccade amplitude, and frequency of eyelid flicks. After pupillary dilatation, the VOR gain decreased for both right (RAC; 1.12 [Formula: see text] 0.12 vs. 1.01 [Formula: see text] 0.16, p = 0.011) and left anterior canals (LACs; 1.15 [Formula: see text] 0.13 vs. 0.96 [Formula: see text] 0.14, p < 0.001), and right posterior canal (RPC, 1.10 [Formula: see text] 0.13 vs. 0.98 [Formula: see text] 0.09, p = 0.001). The corrective saccade amplitudes also decreased significantly for all four vertical canals. The frequency of eyelid flicks, however, did not change. The changes of VOR gain were positively correlated with the lid excursion in RPC (r = 0.629, p = 0.002) and LPC (r = 0.549, p = 0.010). Our study indicates that eyelid position and pupil size should be considered when interpreting the results of video-HITs, especially for the vertical canals. Pupils should be shrunk in a very well-lit room, and artifacts should be prevented by taping or lifting the eyelids as required during video-HITs.

Indexed as

Head Impulse TestSemicircular CanalsAdultArtifactsDioctyl Sulfosuccinic AcidFemaleHumansMiddle AgedReflex, Vestibulo-OcularSaccadesYoung AdultDioctyl Sulfosuccinic AcidHead-impulse testNystagmusPtosisPupilVertigo

Identifiers

PMID37805976
OpenAlexW4387440646

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.