ArticleRadiological physics and technology2023

Verification of optimal conditions for the scattering correction of

Daisuke Izawa, Toshimune Ito, Hiroki Sanada, Takuma Oku, Ayaka Nakamoto, Hitoshi Hiraki

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Daisuke IzawaOffice of Radiation Technology, Keio University Hospital, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
Toshimune ItoDepartment of Radiological, Technology, Faculty of Medical Technology, Teikyo University, 2-11-1 Kaga, Itabashi-ku, Tokyo, 173-8605, Japan. toito@med.teikyo-u.ac.jp.ORCID http://orcid.org/0000-0001-5613-2801
Hiroki SanadaDepartment of Central Radiology, Teikyo University Mizonokuchi Hospital, 5-1-1 Futago, Takatsu-ku, Kawasaki, Kanagawa, 213-8507, Japan.
Takuma OkuDepartment of Radiology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan.
Ayaka NakamotoDepartment of Central Radiology, Juntendo University Hospital, 3-1-3 Hongou, Bunkyo-ku, Tokyo, 113-8431, Japan.
Hitoshi HirakiDepartment of Central Radiology, Teikyo University Mizonokuchi Hospital, 5-1-1 Futago, Takatsu-ku, Kawasaki, Kanagawa, 213-8507, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To identify the optimal scattering correction for 123I-FP-CIT SPECT (DAT-SPECT) using a two-detector whole-body cadmium-zinc-telluride semiconductor detector (C-SPECT) system with a medium-energy high-resolution sensitivity (MEHRS) collimator. The C-SPECT system with the MEHRS collimator assessed image quality and quantification using a striated phantom. Different reconstruction methods and scattering correction settings were compared, including filtered back projection (FBP) and ordered subset expectation maximization (OSEM). Higher %contrast and %CV values were observed > 10% subwindow (SW) for all conditions, with no significant differences between images without scattering correction and those < 7% SW. The FBP images show a greater increase in %CV > 10% SW than the OSEM images. The specific binding ratio in the radioactivity ratio of 8:1 was higher than the true value under all conditions. The C-SPECT system with an MEHRS collimator provided accurate scattering suppression and enabled high-quality imaging for DAT-SPECT. Careful setting of the scattering correction is essential for total count accuracy.

Indexed as

SemiconductorsTomography, Emission-Computed, Single-PhotonCadmiumIodine RadioisotopesPhantoms, ImagingTelluriumTropanesZinc2-carbomethoxy-8-(3-fluoropropyl)-3-(4-iodophenyl)tropaneCadmiumCdZnTeIodine-123Iodine RadioisotopesTelluriumTropanesZinc123I-FP-CITMedium-energy high-resolution sensitivity collimatorScatter correctionsWhole-body cadmium–zinc–telluride semiconductor detector