Evidence map›Paper›PMID 37804455›Full record

ArticleSkeletal radiology2024

Superior metal artifact reduction of tin-filtered low-dose CT in imaging of lumbar spinal instrumentation compared to conventional computed tomography.

Christoph Stern, Florian Wanivenhaus, Andrea B Rosskopf, Mazda Farshad, Reto Sutter

Open access · hybridAbstract read
In one paragraph

Article in Skeletal radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.2field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Christoph SternRadiology, Balgrist University Hospital, Forchstrasse 340, 8008, Zurich, Switzerland. christoph.stern@balgrist.ch.ORCID http://orcid.org/0000-0003-2833-5753
Florian WanivenhausFaculty of Medicine, University of Zurich, Zurich, Switzerland.
Andrea B RosskopfRadiology, Balgrist University Hospital, Forchstrasse 340, 8008, Zurich, Switzerland.
Mazda FarshadFaculty of Medicine, University of Zurich, Zurich, Switzerland.
Reto SutterRadiology, Balgrist University Hospital, Forchstrasse 340, 8008, Zurich, Switzerland.
University of Zurich · CHUniversitätsklinik Balgrist · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo compare the image quality of low-dose CT (LD-CT) with tin filtration of the lumbar spine after metal implants to standard clinical CT, and to evaluate the potential for metal artifact and dose reduction. MATERIALS AND

methodsCT protocols were optimized in a cadaver torso. Seventy-four prospectively included patients with metallic lumbar implants were scanned with both standard CT (120 kV) and tin-filtered LD-CT (Sn140kV). CT dose parameters and qualitative measures (1 = worst,4 = best) were compared. Quantitative measures included noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and the width and attenuation of the most prominent hypodense metal artifact. Standard CT and LD-CT were assessed for imaging findings.

resultsTin-filtered LD-CT was performed with 60% dose saving compared to standard CT (median effective dose 3.22 mSv (quartile 1-3: 2.73-3.49 mSv) versus 8.02 mSv (6.42-9.27 mSv; p < .001). Image quality of CT and tin-filtered low-dose CT was good with excellent depiction of anatomy, while image noise was lower for CT and artifacts were weaker for tin-filtered LD-CT. Quantitative measures also revealed increased noise for tin-filtered low-dose CT (41.5HU), lower SNR (2) and CNR (0.6) compared to CT (32HU,3.55,1.03, respectively) (all p < .001). However, tin-filtered LD-CT performed superior regarding the width and attenuation of hypodense metal artifacts (2.9 mm and -767.5HU for LD-CT vs. 4.1 mm and -937HU for CT; all p < .001). No difference between methods was observed in detection of imaging findings.

conclusionTin-filtered LD-CT with 60% dose saving performs comparable to standard CT in detection of pathology and surgery related complications after lumbar spinal instrumentation, and shows superior metal artifact reduction.

Indexed as

TinTomography, X-Ray ComputedArtifactsHumansLumbar VertebraeRadiation DosageRadiographic Image Interpretation, Computer-AssistedTomographyTinPedicle screwsRadiation dosageSpineTinTomography, X-ray computed

Identifiers

PMID37804455
PMCPMC10858831
OpenAlexW4387424998

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.