ArticleJournal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale2023
A novel intraoperative continuous monitoring method combining dorsal cochlear nucleus action potentials monitoring with auditory nerve test system.
Article in Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Intraoperative auditory monitoring in vestibular schwannoma surgery: Diagnostic accuracy and interventional effectiveness - a systematic review.Neurosurgical review · 2026Pooled it
- Article
- Tympanic Pre-Operative Electrically Evoked Auditory Late Response (TympEALR) as an Alternative to Trans-Tympanic Tests Using Anesthesia in Cochlear Implant Candidacy.Journal of clinical medicine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Highly accurate real-time cochlear nerve monitoring to preserve cochlear nerve function is essential for simultaneous cochlear implantation and ipsilateral vestibular schwannoma resection. In the present study, we developed a novel real-time monitoring system that combines dorsal cochlear nucleus action potential monitoring with intracochlear stimulating electrodes (Auditory Nerve Test System, ANTS). We used this system for a case with vestibular schwannoma resection via the translabyrinthine approach. The monitoring system developed in this study detected highly reliable evoked potentials from the cochlear nerve every two seconds continuously during tumor resection. Near-total tumor resection was achieved, and cochlear implantation was performed successfully after confirming the preservation of cochlear nerve function in a case. The patient's hearing was well compensated by cochlear implantation after surgery. Our novel method continuously achieved real-time monitoring of the cochlear nerve every two seconds during vestibular schwannoma resection. The usefulness of this monitoring system for simultaneous tumor resection and cochlear implantation was demonstrated in the present case. The system developed in this study is compatible with continuous facial nerve monitoring. This highly accurate and novel monitoring method will broaden the number of candidates for this type of surgery in the future.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.