Evidence map›Paper›PMID 37799918›Full record

ArticleJournal of dental sciences2023

Assessment of mechanical characteristics of polyetheretherketone as orthodontic fixed lingual retainers.

Pyi Phyo Win, Daniel De-Shing Chen, Bolormaa Sainbayar, Tzu-Yu Peng, Johnson Hsin-Chung Cheng

Open access · goldAbstract read
In one paragraph

Article in Journal of dental sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.3field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Pyi Phyo WinSchool of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
Daniel De-Shing ChenSchool of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
Bolormaa SainbayarSchool of Dentistry, Mongolian National University of Medical Sciences, Ulaanbaatar City, Mongolia.
Tzu-Yu PengSchool of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
Johnson Hsin-Chung ChengSchool of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
Taipei Medical University Hospital · TWMongolian National University of Medical Sciences · MNTaipei Medical University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background/purpose: Polyetheretherketone (PEEK) is known for its strength, flexibility, biocompatibility, and potential as a replacement for metals in dental appliances; however, uncertainty remains about the mechanical characteristics and dimensions of PEEK-made orthodontic fixed lingual retainers (FLRs). This study aimed to determine the optimal shape of PEEK-made orthodontic FLRs using the finite element method (FEM) and the three-point bending test (TPBT). Materials and methods: Seventy-five three-dimensional PEEK rod-shaped models were created, which included five thicknesses (0.4, 0.6, 0.8, 1.0, and 1.2 mm), five widths (0.7, 0.9, 1.1, 1.3, and 1.5 mm), and three cross-sectional shapes (rectangular, oval, and hemielliptical). A 0.9-mm (0.036-inch) stainless steel wire (SSW) was used as a control and the FEM was used to determine six optimal dimensions among the PEEK models. The selected models were then fabricated and subjected, along with the SSW, to the experimental TPBT to assess their mechanical responses against lingual and biting pressures. Results: The FEM analysis revealed that Von Mises stresses on the PEEK models decreased with an increase in width and thickness. Six optimal shapes of PEEK models were chosen based on acceptable lingual and biting stresses as well as patient comfort compared to the SSW. Furthermore, PEEK models showed significantly lower deformation during the 3.1-mm deflection test than did the SSW, while no notable differences were observed among different sizes of PEEK models. The hemielliptical PEEK model with a thickness of 1.0 mm and width of 1.5 mm was found to be mechanically robust enough to withstand lingual forces, while none of the PEEK models, including the SSW, were able to resist biting forces. Conclusion: Within the limitations of this

Indexed as

Bending testFixed lingual retainerOrthodonticPolyetheretherketoneShape optimization

Identifiers

PMID37799918
PMCPMC10548050
OpenAlexW4379791663

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked