Evidence map›Paper›PMID 37799911›Full record

ArticleJournal of dental sciences2023

Analysis of the accuracy of a dynamic navigation system when performing dental implant surgery with transcrestal sinus floor elevation: A pilot study.

Bin-Zhang Wu, Fei-Fei Ma, Feng Sun

Open access · goldAbstract read
In one paragraph

Article in Journal of dental sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
5.6field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 22 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Bin-Zhang WuFirst Clinical Division, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, PR China.
Fei-Fei MaFirst Clinical Division, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, PR China.
Feng SunFirst Clinical Division, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, PR China.
Peking University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background/purpose: The success of transcrestal sinus floor elevation (TSFE) is primarily reliant upon the experience of the surgeon owing to the limited operative visibility. To evaluate the accuracy associated with the use of a dynamic navigation system when conducting posterior maxilla implant surgery with TSFE. Materials and methods: Twenty-eight implants were placed in 28 patients requiring implantation in the posterior maxilla via a TSFE approach. The drills were used to access the planned position (within 1 mm of the bottom of the maxillary sinus floor) under dynamic navigation system. TSFE was then accomplished using osteotomes and a piezoelectric device. Lastly, the implant was inserted under the dynamic navigation. Three effective deviations between planned and actual implant placement were then measured including angular deviation (AD, degrees), entry point horizontal deviation (EPHD, mm), and apical point horizontal deviation (APHD, mm). Results: The AD, EPHD, and APHD between the planned and actual implant placement were 3.656 ± 1.665°, 1.073 ± 0.686 mm, and 1.086 ± 0.667 mm, respectively. Premolar site AD values were less than those for molar sites ( Conclusion: The accuracy associated with using a dynamic navigation system when conducting posterior maxilla implant surgery via a TSFE approach using piezoelectric devices was comparable. This technique thus achieved appropriate interventional precision and safety while decreasing the morbidity associated with the TSFE approach.

Indexed as

AccuracyDynamic navigationImplant surgeryPiezoelectricTranscrestal sinus floor elevation

Identifiers

PMID37799911
PMCPMC10547952
OpenAlexW4313479436

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.