ArticleBiomedical optics express2023
Method to determine the centration of a lenticule of tissue extracted from a cornea.
Article in Biomedical optics express, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 9 citations in OpenAlex.
- Association between intraoperative decentration and corneal higher-order aberrations in lenticule extraction surgery.BMC ophthalmology · 2026Observational
- Effective optical and treatment zone analysis by means of cross-over differences after lenticule extraction.Heliyon · 2025Article
- Postoperative visual outcomes with lenticule extraction in high myopia: a pilot study.Journal of optometryArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A simple and novel method to analyse the centration of a lenticule of tissue extracted from a cornea has been developed, in which the centre of "mass" of the individual differences between post and preoperative maps of several corneal metrics represents the lenticule centration and its spatial distance to a reference point (aimed centration) determines the decentration. Different parameters have been evaluated to weight the centre of "mass". The robustness of the methods has been evaluated using perturbation analysis (adding white-noise to the data) based on realistic uncertainties. A clipped analysis has been performed to prevent large, localised areas of lacking/missing data from affecting the centre of "mass". The method has been tested on a pilot cohort of clinical data showing 30% and 63% of the treatments within 200 µm of decentration for corneal thickness and refractive equivalent power, respectively. Except for anterior elevation with a total standard deviation of 17 µm, all other metrics show excellent precision of ∼5 µm. The method provides a reliable and objective way to determine the centration of a lenticule of tissue extracted from a cornea and it can be applied to any topo- or tomographic derived metric.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.