Evidence map›Paper›PMID 37797649›Full record

ArticlePhysics in medicine and biology2023

Bubble cloud characteristics and ablation efficiency in dual-frequency intrinsic threshold histotripsy.

Connor Edsall, Laura Huynh, Timothy L Hall, Eli Vlaisavljevich

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Contrast-Enhanced Imaging of Histotripsy Bubble Clouds Using Chirp-Coded Excitation and Volterra Filtering.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2023
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

Connor EdsallDepartment of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, 325 Stanger St., Blacksburg, VA, 24061, United States of America.ORCID 0000-0001-6876-1496
Laura HuynhDepartment of Materials Science and Engineering, Virginia Polytechnic Institute and State University, 445 Old Turner St., Blacksburg, VA 24061, United States of America.
Timothy L HallBiomedical Engineering, University of Michigan, Carl A. Gerstacker Building, 2200 Bonisteel Blvd, Ann Arbor, MI 48109-2133, United States of America.ORCID 0000-0002-4867-2856
Eli VlaisavljevichDepartment of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, 325 Stanger St., Blacksburg, VA, 24061, United States of America.ORCID 0000-0002-4097-6257

Funding

Developing Methods for Precise, Safe and Target-location Specific Histotripsy of Liver TumorsR01CA262474 · NCI · UNIVERSITY OF WISCONSIN-MADISON · PI ZIEMLEWICZ, TIMOTHY J · 2021 to 2025
$2.4M
Deploying Histotripsy Based Tumor Ablation Strategies to Treat Pancreatic CancerR01CA269811 · NCI · VIRGINIA POLYTECHNIC INST AND ST UNIV · PI Irving C Allen · 2022 to 2026
$2.0M
NCI NIH HHS R01 CA262474NCI NIH HHS R01 CA269811
6 · The paper itself

Abstract

Histotripsy is a non-thermal focused ultrasound ablation method that destroys tissue through the generation and activity of acoustic cavitation bubble clouds. Intrinsic threshold histotripsy uses single-cycle pulses to generate bubble clouds when the dominant negative pressure phase exceeds an intrinsic threshold of ∼25-30 MPa. The ablation efficiency is dependent upon the size and density of bubbles within the bubble cloud. This work investigates the effects of dual-frequency pulsing schemes on the bubble cloud behavior and ablation efficiency in intrinsic threshold histotripsy. A modular 500 kHz:3 MHz histotripsy transducer treated agarose phantoms using dual-frequency histotripsy pulses with a 1:1 pressure ratio from 500 kHz and 3 MHz frequency elements and varying arrival times for the 3 MHz pulse relative to the arrival of the 500 kHz pulse (-100 ns, 0 ns, and +100 ns). High-speed optical imaging captured cavitation effects to characterize bubble cloud and individual bubble dynamics. The effects of dual-frequency pulsing on lesion formation and ablation efficiency were also investigated in red blood cell (RBC) phantoms. Results showed that the single bubble and bubble cloud size for dual-frequency cases were intermediate to published results for the component single-frequencies of 500 kHz and 3 MHz. Additionally, bubble cloud size and dynamics were shown to be altered by the arrival time of the 3 MHz pulse with respect to the 500 kHz pulse, with more uniform cloud expansion and collapse observed for early (-100 ns) arrival. Finally, RBC phantom experiments showed that dual-frequency exposures were capable of generating precise lesions with smaller areas and higher ablation efficiencies than previously published results for 500 kHz or 3 MHz. Overall, results demonstrate dual-frequency histotripsy's ability to modulate bubble cloud size and dynamics can be leveraged to produce precise lesions at higher ablation efficiencies than previously observed for single-frequency pulsing.

Indexed as

High-Intensity Focused Ultrasound AblationLithotripsyErythrocytesPhantoms, ImagingTransducersablationbubble cloud dynamicscavitationdual-frequencyfrequencyhistotripsy

Identifiers

PMID37797649
PMCPMC10627095

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.