ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2026
The Aristotle 18 and 24 microwires in neuroIntervention: Early experience at a single centre.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Optimizing catheter centering enhances mechanical thrombectomy success: Performance difference in cases using novel macrowires versus traditional microwires.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- First-pass efficacy with simplicity: Macrowire-only direct aspiration technique in posterior circulation mechanical thrombectomy.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- A single-center study of the RED 72 reperfusion catheter with SENDit technology in proximal large vessel occlusions.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Overcoming the black box of aspiration thrombectomy in acute ischemic stroke: An early clinical experience of using contrast injections to understand clot-catheter interactions.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BackgroundCurrent neurointerventional procedures are expanding the use of large bore microcatheters, of up to 0.033" inner diameters, to accommodate intrasaccular flow disruptors or neck-bridging devices, including flow diverters. The use of large bore microwires may mitigate the ledge gap between wire and catheter, facilitate navigation and offer support in distal tortuous anatomy. We aim to report our early experience using the novel Aristotle (Scientia Vascular, West Valley City, UT) 18 and 24 microwires in neurovascular interventions.MethodsWe analysed neurointerventional procedures in which the Aristotle 18 and 24 microwires were used at a single centre. Prospectively collected data, from March 2022 to February 2023, including patient's clinical outcome (successful target vessel, aneurysm catheterisation, peri-procedural complications (thromboembolic, haemorrhagic, vessel dissection or perforation) were analysed.ResultsOverall, the use of Aristotle 18 and 24 microwires was recorded in 84 neurointerventional procedures during the study period, including endovascular aneurysm treatment (n = 30), endovascular thrombectomy (n = 46), dural venous sinus manometry/stent placement (n = 7), and extracranial carotid artery stent placement (n = 1). The Aristotle 18 microwire was used in conjunction with 0.021" microcatheters and the Aristotle 24 microwire with the 0.027 or 0.033" microcatheters. In all cases (100%), the target vessel or aneurysm was reached with the microwire, allowing seamless advancement of the selected microcatheters. No procedure related complications were recorded.ConclusionsThe use of the Aristotle 18 and 24 microwires in neurointerventional procedures is feasible and safe. The microwires provide reduced ledge gap, improved torquability, support and safety over standard 0.014" microwires.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.