ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2026
Early clinical experience with the new generation Pipeline Vantage flow diverter in the treatment of unruptured saccular aneurysms using short-term dual antiplatelet therapy.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 2 syntheses or guidelines pooled it, 12 citations in OpenAlex.
- Flow diverter treatment for saccular unruptured intracranial aneurysms: A systematic review focussing on study quality and initial outcomes.European stroke journal · 2026Pooled it
- Initial Experience with the Pipeline Vantage Flow Diverter for Intracranial Aneurysms: A Systematic Review and Meta-Analysis.AJNR. American journal of neuroradiology · 2025Pooled it
- Midterm Results on Pipeline Vantage Embolization Device (MR-PVED): First Reported Experience in Asia.Asian journal of neurosurgery · 2026Article
- Safety and efficacy of the pipeline vantage flow diverter for the treatment of saccular aneurysms in the posterior cerebral circulation.The neuroradiology journal · 2026Article
- Flow diverter treatment for saccular unruptured intracranial aneurysms: A systematic review focussing on study quality and initial outcomes.European stroke journal · 2025Article
- Multicenter Experience with the Pipeline Flex and Vantage with Shield Technology for Intracranial Aneurysm Treatment.AJNR. American journal of neuroradiology · 2024Observational
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
PurposeThe Pipeline Vantage flow diverter with Shield technology (PV) used in this study is a 4th-generation flow diverter (FD) designed to reduce thrombogenicity, promote endothelialization of the implant and increase efficiency in achieving aneurysm closure. In this study, we report the aneurysm occlusion rate, complication rate and clinical outcome with short-term dual antiplatelet therapy (DAPT) in the treatment of unruptured intracranial saccular aneurysms using the PV.MethodsWe retrospectively identified patients treated between September 2021 and January 2023 with the PV and subsequently underwent short-term DAPT for 3 months. Patient and aneurysm characteristics, peri- and post-procedural complications, clinical outcomes and the grade of aneurysm occlusion were documented.ResultsThirty patients with 32 aneurysms were treated. Successful FD implantation was achieved in all cases (100%). No periprocedural complications were documented. The overall symptomatic complication rate was 10% and the neurologic, treatment-related symptomatic complication rate was 6.6%. Only one symptomatic complication (3.3%) was device-related. Permanent clinical deterioration occurred in 2/30 patients (6.6%), leading to deterioration of the mRS within the first 3 months after treatment. No mortality was documented. The rate of complete aneurysm occlusion after 3 months and after a mean imaging follow-up of 9.9 months was 65.6% and 75%, respectively.ConclusionImplantation of the PV for the treatment of saccular intracranial aneurysms achieves a good aneurysm occlusion rate with a low rate of complications. In addition, the use of short-term DAPT after PV implantation appears to be safe.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.