Less wear in deep-dished mobile compared to fixed bearing total knee arthroplasty of the same design at 5-year follow-up: a randomised controlled model-based Roentgen stereophotogrammetric analysis trial.

S Kalaai, J Most, B van Dun, B L Kaptein, P B J Tilman, B Boonen, M G M Schotanus

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

S KalaaiDepartment of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands. soufyankalaai@hotmail.com.ORCID http://orcid.org/0000-0002-3840-0718
J MostDepartment of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands.
B van DunDepartment of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands.
B L KapteinDepartment of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands.
P B J TilmanDepartment of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands.
B BoonenDepartment of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands.
M G M SchotanusDepartment of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of this prospective randomised controlled study was to compare wear characteristics and functional outcome between deep-dished mobile bearing (MB) and fixed bearing (FB) cemented total knee arthroplasty (TKA). We hypothesised that deep-dished MB reduces polyethylene wear and improves patient-reported outcome measures.

methodsA total of 50 patients were randomised to receive a MB or FB tibia component of the same cemented TKA design. Patients were evaluated over a 5-year follow-up period. Medial and lateral wear were assessed using model-based Roentgen Stereophotogrammetric Analysis (RSA) and compared with the direct postoperative minimal joint space measurement. Functional outcome was assessed by the clinician-derived KSS and OKS, WOMAC, LEAS, and FJS-12. All data were derived using a general linear mixed model.

resultsAt 5-year follow-up, decreased wear in the MB compared to the FB group was observed on the lateral side (0.07 ± 0.17 mm, p = 0.026), but not on the medial side (0.31 ± 0.055 mm, p = 0.665). Functional outcomes improved with a statistical significant effect over time, with no significant differences between groups (all p > 0.17).

conclusionThis model-based RSA study with 5-year follow-up showed that cemented deep-dished MB reduced lateral polyethylene wear as compared to FB in a single TKA system, whilst clinical outcomes were comparable. Longer follow-up is needed to establish clinical implications of these altered wear patterns and determine type of wear. LEVEL OF EVIDENCE: Level 1 randomised controlled trial.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeHumansKnee JointPolyethyleneProspective StudiesProsthesis DesignPolyethyleneCruciate-retaining TKADeep-dished mobile bearingFunctional outcomeModel-based Roentgen stereophotogrammetric analysisPROMsTotal knee arthroplastyWear caractheristics