Evidence map›Paper›PMID 37796284›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Biomechanical analysis of different THA cementless femoral stem designs in physiological and osteoporotic bone during static loading conditions.

Matteo Formica, Andrea Zanirato, Edoardo Bori, Tullio Andrea Revetria, Juljana Ditting, Bernardo Innocenti

Erratum issuedOpen access · greenAbstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Matteo FormicaDipartimento di Scienze Chirurgiche e Diagnostiche Integrate (DISC), Università Degli Studi di Genova, Viale Benedetto XV N°6, 16132, Genoa, Italy.
Andrea ZaniratoDipartimento di Scienze Chirurgiche e Diagnostiche Integrate (DISC), Università Degli Studi di Genova, Viale Benedetto XV N°6, 16132, Genoa, Italy.
Edoardo BoriBEAMS Department (Bio Electro and Mechanical Systems), École Polytechnique de Bruxelles, Université Libre de Bruxelles, Av. F. Roosevelt, 50 CP165/56, 1050, Brussels, Belgium. edoardo.bori@gmail.com.ORCID http://orcid.org/0000-0002-1670-8359
Tullio Andrea RevetriaDipartimento di Scienze Chirurgiche e Diagnostiche Integrate (DISC), Università Degli Studi di Genova, Viale Benedetto XV N°6, 16132, Genoa, Italy.
Juljana DittingBEAMS Department (Bio Electro and Mechanical Systems), École Polytechnique de Bruxelles, Université Libre de Bruxelles, Av. F. Roosevelt, 50 CP165/56, 1050, Brussels, Belgium.
Bernardo InnocentiBEAMS Department (Bio Electro and Mechanical Systems), École Polytechnique de Bruxelles, Université Libre de Bruxelles, Av. F. Roosevelt, 50 CP165/56, 1050, Brussels, Belgium.
Ospedale Policlinico San Martino · ITUniversité Libre de Bruxelles · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe influence of THA stem design on periprosthetic femoral fractures (PFFs) risk is subject of debate. This study aims to compare the effects of different cementless stem designs on stress-strain distributions in both physiological and osteoporotic femur under various loading conditions. MATERIALS: A biomechanical study using finite-element analysis was conducted. Four models were developed: three with implanted femurs and a native one chosen as control. Each model was analyzed for both healthy and osteoporotic bone. The following stem designs were examined: short anatomical stem with femoral neck preservation, double-wedge stem, and anatomical standard stem. Three loading conditions were assessed: gait, sideways falling, and four-point bending.

resultsDuring gait in physiological bone, the anatomical stem and the short anatomical stem with femoral neck preservation showed stress distribution similar to the native model. The double-wedge stem reduced stress in the proximal area but concentrated it in the meta-diaphysis. In osteoporotic bone, the double-wedge stem design increased average stress by up to 10%. During sideways falling, the double-wedge stem exhibited higher stresses in osteoporotic bone. No significant differences in average stress were found in any of the studied models during four-point bending.

conclusionIn physiological bone, anatomical stems demonstrated stress distribution comparable to the native model. The double-wedge stem showed uneven stress distribution, which may contribute to long-term stress shielding. In the case of osteoporotic bone, the double-wedge stem design resulted in a significant increase in average stress during both gait and sideways falling, potentially indicating a higher theoretical risk of PFF.

Indexed as

Arthroplasty, Replacement, HipFemoral FracturesHip ProsthesisOsteoporosisPeriprosthetic FracturesFemurHumansProsthesis DesignCementlessPeriprosthetic femoral fracturesStem designTHA

Identifiers

PMID37796284
OpenAlexW4387372306

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.