Evidence map›Paper›PMID 37795969›Full record

ArticleAnalytical chemistry2023

Enhancing Extracellular Vesicle Analysis by Integration of Large-Volume Sample Stacking in Capillary Electrophoresis with Asymmetrical Flow Field-Flow Fractionation.

Ziting Gao, Zongbo Li, Zachary Hutchins, Quanqing Zhang, Wenwan Zhong

Open access · greenAbstract read
In one paragraph

Article in Analytical chemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
5.7field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 27 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Review
  6. Review
  7. Review
  8. Review
  9. Review
  10. [Annual review of capillary electrophoresis technology in 2023].Se pu = Chinese journal of chromatography · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Ziting GaoDepartment of Chemistry, University of California - Riverside, Riverside, California 92521, United States.
Zongbo LiDepartment of Chemistry, University of California - Riverside, Riverside, California 92521, United States.
Zachary HutchinsDepartment of Chemistry, University of California - Riverside, Riverside, California 92521, United States.
Quanqing ZhangInstitute for Integrative Genome Biology, Department of Botany and Plant Sciences, University of California - Riverside, Riverside, California 92521, United States.
Wenwan ZhongDepartment of Chemistry, University of California - Riverside, Riverside, California 92521, United States.ORCID 0000-0002-3317-3464
University of California, Riverside · US

Funding

Research Training in Environmental ToxicologyT32ES018827 · NIEHS · UNIVERSITY OF CALIFORNIA RIVERSIDE · PI Yinsheng Wang · 2010 to 2026
$5.3M
An LTQ-Orbitrap Elite with ETD for the Keck Proteomics FacilityS10OD010669 · OD · UNIVERSITY OF CALIFORNIA RIVERSIDE · PI WANG, YINSHENG · 2013 to 2013
$600k
NIEHS NIH HHS T32 ES018827NIH HHS S10 OD010669
6 · The paper itself

Abstract

Extracellular vesicles (EVs) play important roles in cell-cell communication and pathological development. Cargo profiling for the EVs present in clinical specimens can provide valuable insights into their functions and help discover effective EV-based markers for diagnostic and therapeutic purposes. However, the highly abundant and complex matrix components pose significant challenges for specific identification of low-abundance EV cargos. Herein, we combine asymmetrical flow field-flow fractionation (AF4) with large-volume sample stacking and capillary electrophoresis (LVSS/CE), to attain EVs with high purity for downstream protein profiling. This hyphenated system first separates the EVs from the contamination of smaller serum proteins by AF4, and second resolves the EVs from the coeluted, nonvesicular matrix components by CE following LVSS. The optimal LVSS condition permits the injection of 10-fold more EVs into CE compared to the nonstacking condition without compromising separation resolution. Collection and downstream analysis of the highly pure EVs after CE separation were demonstrated in the present work. The high EV purity yields a much-improved labeling efficiency when detected by fluorescent antibodies compared to those collected from the one-dimension separation of AF4, and permits the identification of more EV-specific cargos by LC-MS/MS compared to those isolated by ultracentrifugation (UC), the exoEasy Maxi Kit, and AF4. Our results strongly support that AF4-LVSS/CE can improve EV isolation and cargo analysis, opening up new opportunities for understanding EV functions and their applications in the biomedical fields.

Indexed as

Extracellular VesiclesTandem Mass SpectrometryBlood ProteinsChromatography, LiquidUltracentrifugationBlood Proteins

Identifiers

PMID37795969
PMCPMC10947528
OpenAlexW4387357603

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.