Skinfolds compressibility and digital caliper's time response in skinfold measurement in male and female young adults.
Article in Journal of the International Society of Sports Nutrition, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 5 citations in OpenAlex.
- Effects of instrument assisted and functional soft tissue mobilization on hamstring flexibility and skinfold thickness in sedentary adults.Scientific reports · 2026Trial
- Skinfolds Measurement Protocols and Standards: A Narrative Review.Advances in nutrition (Bethesda, Md.) · 2026Review
- Evaluation of Skinfolds Based Predictive Equations for Estimating Body Fat Percentage in Older Adults: A Comparison Using Digital Adipometer (Lipowise) and Dual-Energy X-Ray Absorptiometry (DXA).Clinical obesity · 2026Article
- Applying machine learning to associate clinical factors with malnutrition risk in peritoneal dialysis patients: an internally validated interpretable model.Frontiers in nutrition · 2026Article
- [Interchangeability of different indirect methods for determining body composition].Problemy endokrinologii · 2025Observational
- Validity and agreement between dual-energy X-ray absorptiometry, anthropometry and bioelectrical impedance in the estimation of fat mass in young adults.Frontiers in nutrition · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe skinfold caliper reading of the skinfold thickness depends on its dynamic compressibility. This has led to the fact that, while it is indicated that skinfold readings should be taken when the reading is stable, there is no consensus on at what second the reading should be taken after the application of the skinfold caliper. The new Lipowise PRO digital skinfold caliper was used to analyze the evolution of skinfold readings under skinfold caliper pressure. The aim of the present investigation were: a) to analyze the evolution of the reading time of individual skinfolds when subjected to skinfold caliper pressure and when the skinfold reading reaches stability; b) to describe the physical behavior of skinfold tissues' time response to skinfold caliper pressure, and to explore differences between sites and subjects' skinfolds compressibility; and c) to analyze the sex differences in both the reading and the evolution of the skinfold over time.
methodsA descriptive cross-sectional design was followed with a convenience sample of 165 healthy young adults (79 males and 86 females), with eight skinfolds measured using the Lipowise PRO skinfold caliper. The Lipowise PRO skinfold caliper uses a programmable reading time allowing for the measurement of the skinfold's thickness at a rate of 100 times per second, and monitoring skinfold behavior over the 3-second measurement period, thereby enabling the assessment of the tissue response to the constant force exerted by the skinfold caliper jaws.
resultsAll skinfolds showed statistical differences in terms of compressibility characteristics (
conclusionA skinfold caliper application, using the digital caliper Lipowise PRO, of three seconds may be sufficient for achieving stability in the measurement and for obtaining the minimum value for most individual and sum of skinfolds. However, there are certain skinfolds that may require more time when performed on certain individuals, which vary according to sex.