Evidence map›Paper›PMID 37794700›Full record

ArticleJournal of applied clinical medical physics2023

Isodose surface differences: A novel tool for the comparison of dose distributions.

Stefanos Diamantopoulos, Kalliopi Platoni, Pantelis Karaiskos, Vassilis Kouloulias, Efstathios Efstathopoulos

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Stefanos Diamantopoulos2nd Department of Radiology, University General Hospital "Attikon", 1 Rimini Street, National and Kapodistrian University of Athens, Chaidari, Greece.ORCID https://orcid.org/0000-0003-2218-8860
Kalliopi Platoni2nd Department of Radiology, University General Hospital "Attikon", 1 Rimini Street, National and Kapodistrian University of Athens, Chaidari, Greece.ORCID https://orcid.org/0000-0003-2977-7895
Pantelis KaraiskosMedical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece.
Vassilis Kouloulias2nd Department of Radiology, University General Hospital "Attikon", 1 Rimini Street, National and Kapodistrian University of Athens, Chaidari, Greece.
Efstathios Efstathopoulos2nd Department of Radiology, University General Hospital "Attikon", 1 Rimini Street, National and Kapodistrian University of Athens, Chaidari, Greece.
National and Kapodistrian University of Athens · GRRoyal Marsden NHS Foundation Trust · GB

Funding

European Social Fund-ESFHuman Resources Development, Education and Lifelong Learning 2014-2020,″ MIS:5048154
6 · The paper itself

Abstract

backgroundComparing dose distributions is a routine task in radiotherapy, mainly in patient-specific quality assurance (PSQA). Currently, the evaluation of the dose distributions is being performed mainly with statistical methods, which could underestimate the clinical importance of the spotted differences, as per the literature. PURPOSE: This paper aims to provide proof-of-concept for a novel dose distribution comparison method based on the difference of the isodose surfaces. The new method connects acceptance tolerance to QA limitations (equipment capabilities) and integrates a clinical approach into the analysis procedure.

methodsThe distance of dose points from the isocenter can be used as a function to define the shape of an isodose surface expressed as a histogram. Isodose surface differences (ISD) are defined as the normalized differences of reference and evaluated surface histograms plotted against their corresponding isodose. Acceptance tolerances originate from actual QA tolerances and are presented clinically intuitively. The ISD method was compared to the gamma index using intentionally erroneous VMAT and IMRT plans.

resultsResults revealed that the ISD method is sensitive to all errors induced in the plans. Discrepancies are presented per isodose, enabling the evaluation of the plan in two regions representing PTV and Normal Tissue. ISD manages to flag errors that would remain undetected under the gamma analysis.

conclusionThe ISD method is a meaningful, QA-related, registration-free, and clinically oriented technique of dose distribution evaluation. This method can be used either as a standalone or an auxiliary tool to the well-established evaluation procedures, overcoming significant limitations reported in the literature.

Indexed as

Radiotherapy, ConformalRadiotherapy, Intensity-ModulatedHumansRadiotherapy DosageRadiotherapy Planning, Computer-Assisteddose measurement, PSQA, Quality AssuranceIMRT/VMAT

Identifiers

PMID37794700
PMCPMC10647989
OpenAlexW4387356842

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.