A side-by-side comparison of the new VITEK MS PRIME and the MALDI Biotyper sirius in the clinical microbiology laboratory.

Philipp Thelen, Sandra Graeber, Erika Schmidt, Axel Hamprecht

Abstract read
In one paragraph

Article in European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Comparative analytical performance of Autof MS2600 and Biotyper Sirius for rapid MALDI-TOF MS identification of microorganisms from positive blood cultures.European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Philipp ThelenInstitute of Medical Microbiology and Virology, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany. philipp.thelen@uol.de.ORCID http://orcid.org/0000-0001-5073-8829
Sandra GraeberInstitute of Medical Microbiology and Virology, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany.
Erika SchmidtInstitute for Medical Microbiology and Virology, Klinikum Oldenburg, Oldenburg, Germany.ORCID http://orcid.org/0009-0003-2205-0068
Axel HamprechtInstitute of Medical Microbiology and Virology, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany.ORCID http://orcid.org/0000-0003-1449-5780

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aims to evaluate the performance of two latest generation matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) systems in routine laboratory settings, focusing on turnaround time (TAT), time to results (TTR), hands-on time, and identification rate.

methodsWe conducted a time and motion study on three workflow scenarios to simulate different laboratory settings. Overall, 618 bacterial isolates from a tertiary hospital's laboratory were processed using the VITEK MS PRIME (bioMérieux) and the MALDI Biotyper sirius (Bruker Daltonics) and their corresponding databases VITEK IVD Database 3.2 and MBT reference library 12.

resultsThe target preparation process showed no significant difference in TAT, but the Biotyper workflow had a shorter hands-on time by 3 to 6 min. In the measurement process, TTR was three to five times shorter for the Biotyper sirius while hands-on time was significantly shorter for VITEK MS PRIME (approximately 1.5 min per target). The identification rate without retesting was 97.9% for VITEK MS PRIME and 98.9% for Biotyper sirius. Both systems achieved 100% agreement at genus and 96.2% at species level.

conclusionBoth systems exhibited excellent identification rates for routine bacterial isolates. Due to its high speed, the Biotyper sirius is suited for laboratories with high sample throughput and a workflow designed for processing larger batches. The VITEK MS PRIME, with its "load and go" system accommodating up to 16 targets, reduces hands-on time, making it a reasonable choice for laboratories with fewer identifications overall but a higher number of targets and a workflow designed for parallel processing on different workstations.

Indexed as

LaboratoriesHumansSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationLaboratory managementMALDI Biotyper siriusMALDI-TOF MSRapid identificationVITEK MS PRIME

Identifiers

PMID37794128
PMCPMC10587274

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.