GuidelineJournal of applied clinical medical physics2023
AAPM Medical Physics Practice Guideline 8.b: Linear accelerator performance tests.
Guideline in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed, 2 syntheses or guidelines pooled it, 39 citations in OpenAlex.
- AAPM-RSS Medical Physics Practice Guideline 9.b: SRS-SBRT.Journal of applied clinical medical physics · 2025Guideline
- AAPM Medical Physics Practice Guideline 8.b: Linear accelerator performance tests.Journal of applied clinical medical physics · 2023Guideline
- Automated linac downtime tracking across 4 radiation oncology clinics within a single hospital system utilizing statistical process control.Journal of applied clinical medical physics · 2026Article
- A centralized hybrid model for regulatory inspection readiness in a multi-site radiation oncology system.Journal of applied clinical medical physics · 2026Article
- ESTRO consensus recommendations on total skin electron beam technique - Endorsed by ILROG.Physics and imaging in radiation oncology · 2026Article
- Computer vision mechanical QA: Development, characterization, and five years of clinical performance.Journal of applied clinical medical physics · 2026Article
- To measure or not to measure: Is pre-treatment measurement of all IMRT plans a legacy practice?Medical physics · 2026Article
- Sensitivity and concordance study of an open source EPID-based linear accelerator test suite.Journal of applied clinical medical physics · 2026Article
- Assessment of the mechanical performance of a novel CT-linac treatment couch.Frontiers in oncology · 2026Article
- Clinical evaluation of the golden beam data in the monaco treatment planning system for the harmony pro and infinity linear accelerators.Journal of applied clinical medical physics · 2026Article
- Initial follow-up of mechanical QC tests for RapidArc Dynamic (RAD).Journal of applied clinical medical physics · 2026Article
- A pathway away from measurement-based patient-specific QA: A review of contemporary quality assurance for external-beam radiotherapy sub-systems.Journal of applied clinical medical physics · 2025Review
- Comparison of log file-based and measurement-based QA for detecting MLC positional errors and evaluating dosimetric impacts of MLC defects.Journal of applied clinical medical physics · 2025Article
- Evaluating Monaco 6.2.2 in complex radiotherapy across matched LINACs: improved MLC modelling and dose accuracy with virtual source model 2.0.Physical and engineering sciences in medicine · 2025Article
- Radiotherapy medical physics in the Philippines: A contemporary overview.Journal of applied clinical medical physics · 2025Article
- Commissioning and clinical implementation of low dose dual-field rotational TSET.Journal of applied clinical medical physics · 2025Article
- Evaluation of the TrueBeam machine-performance-check (MPC): Collimator device check (CDC).Journal of applied clinical medical physics · 2025Article
- Article
- High-precision localization of radiation isocenter using Winston-Lutz test: Impact of collimator angle, phantom position, and field size.Journal of applied clinical medical physics · 2025Article
- Hybrid Monte Carlo model for efficient tissue Cherenkov emission estimation to assess changes from beam size, energy and incidence.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors at 14 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The purpose of this guideline is to provide a list of critical performance tests to assist the Qualified Medical Physicist (QMP) in establishing and maintaining a safe and effective quality assurance (QA) program. The performance tests on a linear accelerator (linac) should be selected to fit the clinical patterns of use of the accelerator and care should be given to perform tests which are relevant to detecting errors related to the specific use of the accelerator. Current recommendations for linac QA were reviewed to determine any changes required to those tests highlighted by the original report as well as considering new components of the treatment process that have become common since its publication. Recommendations are made on the acquisition of reference data, routine establishment of machine isocenter, basing performance tests on clinical use of the linac, working with vendors to establish QA tests and performing tests after maintenance and upgrades. The recommended tests proposed in this guideline were chosen based on consensus of the guideline's committee after assessing necessary changes from the previous report. The tests are grouped together by class of test (e.g., dosimetry, mechanical, etc.) and clinical parameter tested. Implementation notes are included for each test so that the QMP can understand the overall goal of each test. This guideline will assist the QMP in developing a comprehensive QA program for linacs in the external beam radiation therapy setting. The committee sought to prioritize tests by their implication on quality and patient safety. The QMP is ultimately responsible for implementing appropriate tests. In the spirit of the report from American Association of Physicists in Medicine Task Group 100, individual institutions are encouraged to analyze the risks involved in their own clinical practice and determine which performance tests are relevant in their own radiotherapy clinics.