ArticleAbdominal radiology (New York)2024

Image quality optimization: dynamic contrast-enhanced MRI of the abdomen at 3T using a continuously acquired radial golden-angle compressed sensing acquisition.

Jiangyang Pan, Xian Shao, Hui Liu, Yang Li, Qi Wang

Open access · hybridAbstract read
In one paragraph

Article in Abdominal radiology (New York), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Jiangyang Pan *Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050000, Hebei, China.
Xian Shao *Department of Anesthesiology, The Fourth Hospital of Shijiazhuang, Shijiazhuang, 050000, Hebei, China.
Hui LiuDepartment of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050000, Hebei, China. liuhui19800913@126.com.ORCID http://orcid.org/0009-0003-8780-457X
Yang LiDepartment of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050000, Hebei, China. 1281467164@qq.com.
Qi WangDepartment of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050000, Hebei, China. ja1109w@163.com.
Hebei Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe image quality of continuously acquired free-breathing Dynamic Contrast-Enhanced (DCE) golden-angle radial Magnetic Resonance Imaging (MRI) of abdomen suffers from motion artifacts and motion-related blurring. We propose a scheme by minimizing patients' motion status from breathing as well as optimizing the acquiring parameters to improve image quality and diagnostic performance of DCE-MRI with Golden-Angle Radial Sparse Parallel (GRASP) sequence of abdomen.

methodsThe optimization scheme follows two principles: (1) reduce the impact on images from unpredictable and irregulate motions during examination and (2) adjust the sequence parameters to increase the number of radial views in each partition. For the assessment of image quality, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), the severity of radial artifact, the degree of image sharpness, and a visual scoring of image quality with a 5-point scale were assessed.

resultsA total of 64 patients were included in this study before (16 men, 14 women, age: 54.9 ± 17.0) and after (18 men, 16 women, age: 58.6 ± 12.6) the optimization scheme was performed. The results showed that the SNR values of right and left lobe of liver in both plain phase and arterial phase were significantly increased (All P < 0.001) after the GRASP sequence been optimized. Significant improvements in CNR values were observed in the arterial phase (All P < 0.05). The significant differences in scores at each phase for visual scoring of image quality, noise of the right and left lobe of liver, radial artifact, and sharpness indicating that the image quality was significantly improved after the optimization (All P < 0.001).

conclusionOur study demonstrated that the optimized scheme significantly improved the image quality of liver DCE-MRI with GRASP sequence both in plain and arterial phases. The optimized scheme of GRASP sequence could be a superior alternative to conventional approach for the assessment of liver.

Indexed as

AbdomenContrast MediaAdultAgedArtifactsFemaleHumansImage EnhancementImaging, Three-DimensionalLiverMagnetic Resonance ImagingMaleMiddle AgedRespirationContrast MediaAbdominalCompressed sensingDynamic contrast-enhanced magnetic resonance imagingFree breathingGolden angle

Identifiers

PMID37792056
PMCPMC10830580
OpenAlexW4387326920

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.