ArticleUlusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES2023
Biomechanical comparison of three different surgical methods in the surgical treatment of distal tibial metaphyseal fractures. An animal model study.
Article in Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 2 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe aim of this study is to investigate mechanical properties of minimally invasive plate osteosynthesis (MIPO), supracutaneousplating (SP), and unilateral external fixators (UEF) which can be performed for open tibial fractures.
methodsAn unstable diaphysial tibia fracture was created in 60 fresh sheep tibia specimens by performing an osteotomy at the middle of bones. Specimens were divided into 3 groups. Specimens underwent fracture fixation with a standard MIPO technique, im-planting the plate 15 mm from the bone for SP group. Unilateral uniplanar external fixators were achieved for UEF group. First, thirty specimens (10 specimen for each group) were loaded vertically along the tibial axis to 1800 N. Second, other 30 preperated bones were used for cyclical loading to avoid metal fatigue. For dynamic tests, a 350 N force was applied for 10,000 cycles.
resultsIn compression testing (vertical loading up to 1800 N) of the three fixation instruments; construct stiffness was highest in MIPO group when compared with SP and UEF groups. While the stiffness of the MIPO group was similar to SP group, it was statistically higher than UEF group (P=0.08 and P=0.002, respectively). SP group was significantly stiffer than UEF group (P=0.0021). The mean peak load was highest in SP group and lowest in UEF group. The peak load in SP group was similar to the MIPO group, it was statistically higher than the UEF group (P=0.743 and P=0.002, respectively).
conclusionBased on the biomechanical properties from this in vitro animal model study, SP technique was biomechanically stronger than UEF and has similar biomechanical properties with MIPO in terms of axial loading.