Evidence map›Paper›PMID 37791442›Full record

ArticleUlusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES2023

Biomechanical comparison of three different surgical methods in the surgical treatment of distal tibial metaphyseal fractures. An animal model study.

Cem Yıldırım, Osman Görkem Muratoğlu, Samed Ordu, Hasan Ceylan, Duran Can Muslu, Doğan Atlıhan

Open access · bronzeAbstract read
In one paragraph

Article in Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Cem YıldırımDepartment of Orthopaedic and Traumatology, Cam and Sakura City Hospital, Istanbul-Türkiye.
Osman Görkem MuratoğluDepartment of Orthopedic and Traumatology, Istinye University, İstanbul-Türkiye.
Samed OrduDepartment of Orthopedic and Traumatology, Eskişehir Yunus Emre State Hospital, Eskisehir-Türkiye.
Hasan CeylanDepartment of Orthopaedic and Traumatology, Cam and Sakura City Hospital, Istanbul-Türkiye.
Duran Can MusluDepartment of Orthopedic and Traumatology, Brandenburg, Klinikum Dahme Spreewald Achenbach Krankenhaus, Germany.
Doğan AtlıhanDepartment of Orthopedic and Traumatology, Haseki Training and Research Hospital, İstanbul-Türkiye.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe aim of this study is to investigate mechanical properties of minimally invasive plate osteosynthesis (MIPO), supracutaneousplating (SP), and unilateral external fixators (UEF) which can be performed for open tibial fractures.

methodsAn unstable diaphysial tibia fracture was created in 60 fresh sheep tibia specimens by performing an osteotomy at the middle of bones. Specimens were divided into 3 groups. Specimens underwent fracture fixation with a standard MIPO technique, im-planting the plate 15 mm from the bone for SP group. Unilateral uniplanar external fixators were achieved for UEF group. First, thirty specimens (10 specimen for each group) were loaded vertically along the tibial axis to 1800 N. Second, other 30 preperated bones were used for cyclical loading to avoid metal fatigue. For dynamic tests, a 350 N force was applied for 10,000 cycles.

resultsIn compression testing (vertical loading up to 1800 N) of the three fixation instruments; construct stiffness was highest in MIPO group when compared with SP and UEF groups. While the stiffness of the MIPO group was similar to SP group, it was statistically higher than UEF group (P=0.08 and P=0.002, respectively). SP group was significantly stiffer than UEF group (P=0.0021). The mean peak load was highest in SP group and lowest in UEF group. The peak load in SP group was similar to the MIPO group, it was statistically higher than the UEF group (P=0.743 and P=0.002, respectively).

conclusionBased on the biomechanical properties from this in vitro animal model study, SP technique was biomechanically stronger than UEF and has similar biomechanical properties with MIPO in terms of axial loading.

Indexed as

Fractures, OpenTibial FracturesAnimalsBiomechanical PhenomenaBone PlatesFracture Fixation, InternalMinimally Invasive Surgical ProceduresModels, AnimalSheepTibiaTreatment Outcome

Identifiers

PMID37791442
PMCPMC10644082
OpenAlexW4387325980

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.