Evidence map›Paper›PMID 37789572›Full record

ArticleJournal of applied clinical medical physics2024

Markerless dynamic tumor tracking (MDTT) radiotherapy using diaphragm as a surrogate for liver targets.

Maryam Rostamzadeh, Steven Thomas, Marie-Laure Camborde, Tania Karan, Mitchell Liu, Roy Ma, Ante Mestrovic, Bradford Gill, Isaac Tai, Alanah Bergman

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Maryam RostamzadehDepartment of Physics and Astronomy, University of British Columbia, Vancouver, British Columbia, Canada.
Steven ThomasMedical Physics Department, BC Cancer-Vancouver, Vancouver, British Columbia, Canada.
Marie-Laure CambordeMedical Physics Department, BC Cancer-Vancouver, Vancouver, British Columbia, Canada.
Tania KaranMedical Physics Department, BC Cancer-Vancouver, Vancouver, British Columbia, Canada.
Mitchell LiuRadiation Oncology Department, BC Cancer-Vancouver, Vancouver, British Columbia, Canada.
Roy MaRadiation Oncology Department, BC Cancer-Vancouver, Vancouver, British Columbia, Canada.
Ante MestrovicMedical Physics Department, BC Cancer-Vancouver, Vancouver, British Columbia, Canada.
Bradford GillMedical Physics Department, BC Cancer-Vancouver, Vancouver, British Columbia, Canada.
Isaac TaiRadiation Therapy Department, BC Cancer-Vancouver, Vancouver, British Columbia, Canada.
Alanah BergmanMedical Physics Department, BC Cancer-Vancouver, Vancouver, British Columbia, Canada.
BC Cancer Agency · CASpinal Cord Injury BC · CAUniversity of British Columbia · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo assess the feasibility of using the diaphragm as a surrogate for liver targets during MDTT.

methodsDiaphragm as surrogate for markers: a dome-shaped phantom with implanted markers was fabricated and underwent dual-orthogonal fluoroscopy sequences on the Vero4DRT linac. Ten patients participated in an IRB-approved, feasibility study to assess the MDTT workflow. All images were analyzed using an in-house program to back-project the diaphragm/markers position to the isocenter plane. ExacTrac imager log files were analyzed. Diaphragm as tracking structure for MDTT: The phantom "diaphragm" was contoured as a markerless tracking structure (MTS) and exported to Vero4DRT/ExacTrac. A single field plan was delivered to the phantom film plane under static and MDTT conditions. In the patient study, the diaphragm tracking structure was contoured on CT breath-hold-exhale datasets. The MDTT workflow was applied until just prior to MV beam-on.

resultsDiaphragm as surrogate for markers: phantom data confirmed the in-house 3D back-projection program was functioning as intended. In patients, the diaphragm/marker relative positions had a mean ± RMS difference of 0.70 ± 0.89, 1.08 ± 1.26, and 0.96 ± 1.06 mm in ML, SI, and AP directions. Diaphragm as tracking structure for MDTT: Building a respiratory-correlation model using the diaphragm as surrogate for the implanted markers was successful in phantom/patients. During the tracking verification imaging step, the phantom mean ± SD difference between the image-detected and predicted "diaphragm" position was 0.52 ± 0.18 mm. The 2D film gamma (2%/2 mm) comparison (static to MDTT deliveries) was 98.2%. In patients, the mean difference between the image-detected and predicted diaphragm position was 2.02 ± 0.92 mm. The planning target margin contribution from MDTT diaphragm tracking is 2.2, 5.0, and 4.7 mm in the ML, SI, and AP directions.

conclusionIn phantom/patients, the diaphragm motion correlated well with markers' motion and could be used as a surrogate. MDTT workflows using the diaphragm as the MTS is feasible using the Vero4DRT linac and could replace the need for implanted markers for liver radiotherapy.

Indexed as

DiaphragmLung NeoplasmsHumansLiverMotionPhantoms, ImagingThoraxcorrelation modeldiaphragmdynamic tumor trackinglivermarkerlessSABRtracking structurevero4DRT

Identifiers

PMID37789572
PMCPMC10860457
OpenAlexW4387326167

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.