Evidence map›Paper›PMID 37788333›Full record

ArticleJournal of applied clinical medical physics2023

Inter-observer variability in library plan selection on iterative CBCT and synthetic CT images of cervical cancer patients.

Yvonne J M de Hond, Paul M A van Haaren, An-Sofie E Verrijssen, Rob H N Tijssen, Coen W Hurkmans

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Yvonne J M de HondDepartment of Radiation Oncology, Catharina Hospital Eindhoven, Eindhoven, The Netherlands.
Paul M A van HaarenDepartment of Radiation Oncology, Catharina Hospital Eindhoven, Eindhoven, The Netherlands.
An-Sofie E VerrijssenDepartment of Radiation Oncology, Catharina Hospital Eindhoven, Eindhoven, The Netherlands.
Rob H N TijssenDepartment of Radiation Oncology, Catharina Hospital Eindhoven, Eindhoven, The Netherlands.
Coen W HurkmansDepartment of Radiation Oncology, Catharina Hospital Eindhoven, Eindhoven, The Netherlands.
Catharina Ziekenhuis · NLRadboud University Nijmegen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIn the Library-of-Plans (LoP) approach, correct plan selection is essential for delivering radiotherapy treatment accurately. However, poor image quality of the cone-beam computed tomography (CBCT) may introduce inter-observer variability and thereby hamper accurate plan selection. In this study, we investigated whether new techniques to improve the CBCT image quality and improve consistency in plan selection, affects the accuracy of LoP selection in cervical cancer patients. MATERIALS AND

methodsCBCT images of 12 patients were used to investigate the inter-observer variability of plan selection based on different CBCT image types. Six observers were asked to individually select a plan based on clinical X-ray Volumetric Imaging (XVI) CBCT, iterative reconstructed CBCT (iCBCT) and synthetic CTs (sCT). Selections were performed before and after a consensus meeting with the entire group, in which guidelines were created. A scoring by all observers on the image quality and plan selection procedure was also included. For plan selection, Fleiss' kappa (κ) statistical test was used to determine the inter-observer variability within one image type.

resultsThe agreement between observers was significantly higher on sCT compared to CBCT. The consensus meeting improved the duration and inter-observer variability. In this manuscript, the guidelines attributed the overall results in the plan selection. Before the meeting, the gold standard was selected in 76% of the cases on XVI CBCT, 74% on iCBCT, and 76% on sCT. After the meeting, the gold standard was selected in 83% of the cases on XVI CBCT, 81% on iCBCT, and 90% on sCT.

conclusionThe use of sCTs can increase the agreement of plan selection among observers and the gold standard was indicated to be selected more often. It is important that clear guidelines for plan selection are implemented in order to benefit from the increased image quality, accurate selection, and decrease inter-observer variability.

Indexed as

Spiral Cone-Beam Computed TomographyUterine Cervical NeoplasmsCone-Beam Computed TomographyFemaleHumansObserver VariationRadiotherapy Planning, Computer-AssistedCBCTcervixinter-observer variabilityiterative reconstructionlibrary of plansplan-of-the-dayplan selectionsynthetic CT

Identifiers

PMID37788333
PMCPMC10647946
OpenAlexW4387309334

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.