Evidence map›Paper›PMID 37786371›Full record

ArticleClinical and experimental dental research2023

Investigation of the effects of arch size and implant angulation on the accuracy of digital impression using two intraoral scanners: An in vitro study.

Farideh Geramipanah, Leyla Sadighpour, Leila Payaminia

Open access · goldAbstract read
In one paragraph

Article in Clinical and experimental dental research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Farideh GeramipanahDepartment of Prosthodontics, Faculty of Dentistry, Dental Implant Research Center, Tehran University of Medical Sciences, Tehran, Iran.
Leyla SadighpourDepartment of Prosthodontics, Faculty of Dentistry, Dental Implant Research Center, Tehran University of Medical Sciences, Tehran, Iran.
Leila PayaminiaDepartment of Prosthodontics, Faculty of Dentistry, Dental Implant Research Center, Tehran University of Medical Sciences, Tehran, Iran.ORCID 0000-0002-6151-6620
Tehran University of Medical Sciences · IR

Funding

Dental Research Center Dentistry Research Institute, Tehran University of Medical Sciences 97-01-104-38034
6 · The paper itself

Abstract

objectivesThe aim of this in vitro study was to evaluate the effect of arch size and implant angulation on the accuracy of digital impression in two intraoral scanners of Trios (3shape) and CEREC (Omnicam). MATERIAL AND

methodsFour acrylic models each including six implants at sites 11, 12, 15, 17, 23, and 27 were used, including large with parallel implants, large with angled implants, small with parallel implants, and small with angled implants. After tightening the scan bodies, distance measurements were done using a coordinate measuring machine. Then, each model was scanned 10 times using each scanner. Trueness and precision measurements were finally computed.

resultsThe trueness values ranged from 20 to 260 μm in CEREC Omnicam, and from 40 to 1030 μm in Trios. The precision values ranged from 30 to 190 μm in CEREC Omnicam, while from 50 to 770 μm in Trios. The multivariate test analysis indicated that the measured distances via two scanners and different models show different behaviors. Pairwise interactions between these three variables were significant (p < .05). Pairwise interactions between these variables were also significant. (p < .0001).

conclusionsArch width could affect the accuracy of digital impression; by rotating toward the second quadrant and end points of the scan, errors have increased. However, the angulation of the implants had no effect on the accuracy of digital impression. The CEREC Omnicam scanner showed higher accuracy (trueness and precision) compared to the Trios (3shape) one.

Indexed as

Dental ImplantsImaging, Three-DimensionalComputer-Aided DesignDental Impression TechniqueModels, DentalDental Implantsaccuracyarch sizedigital impressionimplant

Identifiers

PMID37786371
PMCPMC10728534
OpenAlexW4387296896

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.