ArticleJMIR research protocols2023
Evaluating a Novel Infant Heart Rate Detector for Neonatal Resuscitation Efforts: Protocol for a Proof-of-Concept Study.
Article in JMIR research protocols, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 3 citations in OpenAlex.
- Artificial intelligence-based neonatal heart rate monitoring technologies: Systematic review.World journal of clinical pediatrics · 2026Article
- A framework for generative AI-driven extraction of clinical user needs in pediatric device development.Frontiers in digital health · 2026Article
- A portable dry-electrode ECG device for rapid and accurate neonatal heart rate monitoring during resuscitation.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundOver 10 million newborns worldwide undergo resuscitation at birth each year. Pediatricians may use electrocardiogram (ECG), pulse oximetry (PO), and stethoscope in determining heart rate (HR), as HR guides the need for and steps of resuscitation. HR must be obtained quickly and accurately. Unfortunately, the current diagnostic modalities are either too slow, obtaining HR in more than a minute, or inaccurate. With time constraints, a reliable robust heart rate detector (HRD) modality is required. This paper discusses a protocol for conducting a methods-based comparison study to determine the HR accuracy of a novel real-time HRD based on 3D-printed dry-electrode single-lead ECG signals for cost-effective and quick HR determination. The HRD's HR results are compared to either clinical-grade ECG or PO monitors to ensure robustness and accuracy.
objectiveThe purpose of this study is to design and examine the feasibility of a proof-of-concept HRD that quickly obtains HR using biocompatible 3D-printed dry electrodes for single-lead neonatal ECG acquisition. This study uses a novel HRD and compares it to the gold-standard 3-lead clinical ECG or PO in a hospital setting.
methodsA cross-sectional study is planned to be conducted in the neonatal intensive care unit or postpartum unit of a large community teaching hospital in Toronto, Canada, from June 2023 to June 2024. In total, 50 newborns will be recruited for this study. The HRD and an ECG or PO monitor will be video recorded using a digital camera concurrently for 3 minutes for each newborn. Hardware-based signal processing and patent-pending embedded algorithm-based HR estimation techniques are applied directly to the raw collected single-lead ECG and displayed on the HRD in real time during video recordings. These data will be annotated and compared to the ECG or PO readings at the same points in time. Accuracy, F
resultsThe study is ongoing. The projected end date for data collection is around July 2024.
conclusionsThe study will compare the novel patent-pending 3D-printed dry electrode-based HRD's real-time HR estimation techniques with the state-of-the-art clinical-grade ECG or PO monitors for HR accuracy and examines how fast the HRD provides reliable HR. The study will further provide recommendations and important improvements that can be made to implement the HRD for clinical applications, especially in neonatal resuscitation efforts. This work can be seen as a stepping stone in the development of robust dry-electrode single-lead ECG devices for HR estimations in the pediatric population. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/45512.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.