Evidence map›Paper›PMID 37780914›Full record

ArticleFrontiers in surgery2023

Image-guidance in endoscopic pituitary surgery: an in-silico study of errors involved in tracker-based techniques.

Aure Enkaoua, Mobarakol Islam, João Ramalhinho, Thomas Dowrick, James Booker, Danyal Z Khan, Hani J Marcus, Matthew J Clarkson

Open access · goldAbstract read
In one paragraph

Article in Frontiers in surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Augmented reality system for endoscopic pituitary surgery with automatic registration.International journal of computer assisted radiology and surgery · 2025
    Article
  3. PitSurgRT: real-time localization of critical anatomical structures in endoscopic pituitary surgery.International journal of computer assisted radiology and surgery · 2024
    Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Aure EnkaouaWellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK.
Mobarakol IslamWellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK.
João RamalhinhoWellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK.
Thomas DowrickWellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK.
James BookerWellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK.
Danyal Z KhanWellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK.
Hani J MarcusWellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK.
Matthew J ClarksonWellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK.
University College London · GBWellcome / EPSRC Centre for Interventional and Surgical Sciences · GB

Funding

Wellcome Trust
6 · The paper itself

Abstract

Background: Endoscopic endonasal surgery is an established minimally invasive technique for resecting pituitary adenomas. However, understanding orientation and identifying critical neurovascular structures in this anatomically dense region can be challenging. In clinical practice, commercial navigation systems use a tracked pointer for guidance. Augmented Reality (AR) is an emerging technology used for surgical guidance. It can be tracker based or vision based, but neither is widely used in pituitary surgery. Methods: This pre-clinical study aims to assess the accuracy of tracker-based navigation systems, including those that allow for AR. Two setups were used to conduct simulations: (1) the standard pointer setup, tracked by an infrared camera; and (2) the endoscope setup that allows for AR, using reflective markers on the end of the endoscope, tracked by infrared cameras. The error sources were estimated by calculating the Euclidean distance between a point's true location and the point's location after passing it through the noisy system. A phantom study was then conducted to verify the in-silico simulation results and show a working example of image-based navigation errors in current methodologies. Results: The errors of the tracked pointer and tracked endoscope simulations were 1.7 and 2.5 mm respectively. The phantom study showed errors of 2.14 and 3.21 mm for the tracked pointer and tracked endoscope setups respectively. Discussion: In pituitary surgery, precise neighboring structure identification is crucial for success. However, our simulations reveal that the errors of tracked approaches were too large to meet the fine error margins required for pituitary surgery. In order to achieve the required accuracy, we would need much more accurate tracking, better calibration and improved registration techniques.

Indexed as

augmented realitycomputer-assisted surgeryneurosurgerypituitary surgerytracking

Identifiers

PMID37780914
PMCPMC10540627
OpenAlexW4386838573

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.